A portion of the counter surface that is 36 inches (915 mm) long minimum and 36 inches (915 mm) high maximum above the finish floor shall be provided....
Search Results "Fire-Building Surface"
-
904.4.1 Parallel Approach
-
ENTRANCE
Any access point to a building or portion of building or facility used for the purpose of entering....
-
QUESTION: WHAT ACCESSIBILITY STANDARDS APPLY TO PASSENGER RAIL CARS WHEN SPECIFIC DESIGN STANDARDS ARE NOT PROVIDED IN 49 CFR PART 38?
elements of railcars, such as self-service water fountains, ice machines, and condiment dispensers; countertops and dining elements in lounge and bistro cars; and sleeper beds and eating surfaces...
-
§100.201 Premises
Premises means the interior or exterior spaces, parts, components or elements of a building, including individual dwelling units and the public and common use areas of a building....
-
206.4.7 Restricted Entrances
Where restricted entrances are provided to a building or facility, at least one restricted entrance to the building or facility shall comply with 404....
- AJW Architectural Products U592 1.6 Gallon Sanitary Napkin Disposal w/ Keyed Access Panel & Mounted Shelf - Surface Mounted
-
2. a. Accessible route into and throughout the facility
Accessible route into and throughout the facility - The following is a 4-point guideline for ensuring equal access from the parking lot, outdoor walkways, entrances and exists of the buildings...
-
11B-206.4.3 Entrances from tunnels or elevated walkways
Where direct access is provided for pedestrians from a pedestrian tunnel or elevated walkway to a building or facility, all entrances to the building or facility from each tunnel or walkway...
-
11B-206.4.3 Entrances from tunnels or elevated walkways
Where direct access is provided for pedestrians from a pedestrian tunnel or elevated walkway to a building or facility, all entrances to the building or facility from each tunnel or walkway...
- Cal-Royal Products Grade 1 Cylindrical Lockset Calypso CAL Series
- Federal Elevator 360 Passenger Elevator
-
11B-1009.5.4 Transfer steps
The surface of the bottom tread shall extend to a water depth of 18 inches (457 mm) minimum below the stationary water level. Advisory 11B-1009.5.4 Transfer steps....
-
11B-1009.5.4 Transfer steps
The surface of the bottom tread shall extend to a water depth of 18 inches (457 mm) minimum below the stationary water level. Advisory 11B-1009.5.4 Transfer steps....
-
1009.7.4 Stairways
Exception: The minimum clear width of 48 inches (1219 mm) between handrails is not required at stairways serving buildings equipped throughout with an automatic sprinkler system installed...
-
Technically Infeasible
With respect to an alteration of a building or a facility, something that has little likelihood of being accomplished because existing structural conditions would require removing or altering...
-
1009.7.4 Stairways
Exception: The minimum clear width of 48 inches (1220 mm) between handrails is not required at stairways serving buildings equipped throughout with an automatic sprinkler system installed...
-
Transfer Height
Transfer Height Ride seats designed for transfer must be between 14 and 24 inches above the load and unload area surface....
-
R304.5.2 Grade Breaks
Grade breaks shall not be permitted on the surface of ramp runs and turning spaces. Surface slopes that meet at grade breaks shall be flush....
-
11B-406.5.8 Counter slope
Counter slopes of adjoining gutters and road surfaces immediately adjacent to and within 24 inches (610 mm) of the curb ramp shall not be steeper than 1:20....
-
FACILITY
All or any portion of a building, structure, or area, including the site on which such building, structure or area is located, wherein specific services are provided or activities performed...
-
USE OF THE WAY
The only standard building egress system that may require the ability to speak in order to evacuate a building is an emergency phone in an elevator....
-
M302.3.1 Transfer Supports (Section-by-Section Analysis)
Based on the restructure of the transfer surface provisions, described above in Section IV.B.1.b....
- Rebuilding Together Alexandria - Alexandria, VA
-
1012.5 Slope
The slope of the surface of parking spaces and pull-up spaces shall not be steeper than 1:48 in any direction....