The technical requirements include design criteria for the following outdoor constructed features: picnic tables, fire rings, grills, fireplaces, wood stoves, trash and recycling receptacles...
Search Results "Fire-Building Surface"
Commonly Searched Documents
-
Compliance Requirements in Final Rule
-
4.1.5(4) ELEMENTS, SPACES, AND COMMON AREAS
If elements, spaces, or common areas are located in the existing building and they are not provided in the addition, then consideration should be given to making those elements, spaces,...
- Mitsubishi Elevator Group Control System Replacement Panels
-
Tread Width
The visible trail surface measured perpendicular to the direction of travel....
- Bradley Security Grab Bars SA70 Series
-
Road Roughness Measurements
These RTRRMS systems recorded cumulative axle displacement over a given distance and thus reported surface roughness as inches/mile....
-
Issue 1: APS volume
An APS signal should be audible at the beginning of the crosswalk, but no more than 3.7 m (12 ft) from the pushbutton, or to the building line, whichever is closer (2003 MUTCD)....
- ADA Veracity ADA Pro Application
-
3. Terminology
Discussion—Elevation measurements may be taken statically, as with rod and level per Test Method E1364 or dynamically using a rolling inclinometer per Test Method E2133. 3.1.1.2 traveled surface...
-
Selection of Methodology
) information (product type, manufacturer name, warranty/guarantees’ information, and similar data) SECTION #3 Trail pre‐installation specifications (soil type/composition, slope of surface...
-
R306.3.1 Separation
Detectable warning surfaces shall not be used for edge treatment....
-
Energy Consumption During Ambulation
Subjects walked on each surface at their preferred pace, until the physiological variables (energy consumption, heart rate, velocity) had stabilized (2‒3 minutes) and the data collection...
-
1131B.2, Item 1
Vehicle standing spaces and access aisles shall be level with surface slopes not exceeding one unit vertical in 50 units horizontal (2-percent slope) in all directions....
-
Ground Floor
A building or facility always has at least one ground floor and may have more than one ground floor as where a split level entrance has been provided or where a building is built into a...
-
ACCESSIBLE MEANS OF EGRESS
A continuous and unobstructed way of egress travel from any accessible point in a building or facility to a public way. [2010 ADA Standards 106.5] Accessible Means of Egress....
-
11B-801.1 Scope
For example, 806 addresses guest rooms in transient lodging facilities while 902 contains the technical specifications for dining surfaces....
-
703.4.1 Height above Finish Floor or Ground
Tactile characters on signs shall be located 48 inches (1220 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest tactile character and 60 inches...
-
M302.4.2 Clearance Around Base
the diagnostic equipment shall provide a clearance 6 inches (150 mm) high minimum measured from the floor and 36 inches (915 mm) deep minimum measured from the edge of the examination surface...
-
M301.4.2 Clearance Around Base
base of diagnostic equipment shall provide a clearance 6 inches (150 mm) high minimum measured from the floor and 36 inches (915 mm) deep minimum measured from the edge of the examination surface...
-
1002.4.4.3 Permitted Protrusions in Wheelchair Spaces
protrude a distance of 6 inches (150 mm) maximum along the front of the wheelchair space, where located 9 inches (230 mm) minimum and 27 inches (685 mm) maximum above the floor or ground surface...
-
MEASUREMENT TECHNIQUE
MEASUREMENT TECHNIQUE The depth and width are measured along the centerlines of the seat, and the height from the floor to the highest point of the transfer surface: The depth...
-
14.2 Q. If both open and covered parking spaces are provided, how many of each type must be accessible?
., surface parking or garage, that are provided for other residents of the project....
-
801.1 Scope
For example, 806 addresses guest rooms in transient lodging facilities while 902 contains the technical specifications for dining surfaces....
-
4.8.1 General
One fixed showerhead shall be 48 inches (1220 mm) above the floor or ground surface, and one fixed shower head shall be 72 inches (1830 mm) minimum above the floor or ground surface....