For example, one surveyor can take notes and complete forms while another surveyor is obtaining measurements and taking photos....
Search Results "Measuring Technique"
Commonly Searched Documents
- 
    
  
  C. Who should conduct the survey?
  
- 
    
  
  Recessed Doors and Gates: ADA Standard Section 404.2.4.3
  Section 404.2.4.3 covers the current ADA Standards for maneuvering clearances at recessed doors and gates. 
- 
    
  
  Dispensers: ADA Standard Section 604.9.6
  Section 604.9.5 covers the current ADA Standards for dispensers in children's use toilet compartments. 
- 
    
  
  11B-804.2 Clearance
  Clearances are measured from the furthest projecting face of all opposing base cabinets, counter tops, appliances, or walls, excluding hardware. ◼... 
- 
    
  
  §382.21(c)
  (c) If a passenger with a communicable disease meeting the direct threat criteria of this section gives you a medical certificate of the kind outlined in §382.23(c)(2) describing measures... 
- 
    
  
  810.2.2 Dimensions
  Bus stop boarding and alighting areas shall provide a clear length of 96 inches (2440 mm) minimum, measured perpendicular to the curb or vehicle roadway edge, and a clear width of 60 inches... 
- 
    
  
  407.2.1.1 Height
  Call buttons and keypads shall be located within one of the reach ranges specified in 308, measured to the centerline of the highest operable part.... 
- 
    
  
  407.2.1.1 Height
  Call buttons and keypads shall be located within one of the reach ranges specified in 308, measured to the centerline of the highest operable part.... 
- 
    
  
  4.34.6.4(1)
  (1) The counter shall be mounted at a maximum height of 34 in (865 mm) above the floor, measured from the floor to the top of the counter surface, or shall be adjustable or replaceable as... 
- 
    
  
  11B-604.3.1 Size
  Clearance around a water closet shall be 60 inches (1524 mm) minimum measured perpendicular from the side wall and 56 inches (1422 mm) minimum measured perpendicular from the rear wall.... 
- 
    
  
  11B-604.3.1 Size
  Clearance around a water closet shall be 60 inches (1524 mm) minimum measured perpendicular from the side wall and 56 inches (1422 mm) minimum measured perpendicular from the rear wall.... 
- 
    
  
  11B-604.3.1 Size
  Clearance around a water closet shall be 60 inches (1524 mm) minimum measured perpendicular from the side wall and 56 inches (1422 mm) minimum measured perpendicular from the rear wall.... 
- 
    
  
  609.4 Position of Grab Bars
  Grab bars shall be installed in a horizontal position, 33 inches (840 mm) minimum and 36 inches (915 mm) maximum above the finish floor measured to the top of the gripping surface, except... 
- 
    
  
  604.3.1 Size
  Clearance around a water closet shall be 60 inches (1525 mm) minimum measured perpendicular from the side wall and 56 inches (1420 mm) minimum measured perpendicular from the rear wall.... 
- 
    
  
  407.2.1.1 Height
  Call buttons and keypads shall be located within one of the reach ranges specified in 308, measured to the centerline of the highest operable part.... 
- 
    
  
  § 36.304(d)(1)
  (1) Except as provided in paragraph (d)(3) of this section, measures taken to comply with the barrier removal requirements of this section shall comply with the applicable requirements for... 
- 
    
  
  Sec.36.304(c)(2)
  (2) Second, a public accommodation should take measures to provide access to those areas of a place of public accommodation where goods and services are made available to the public.... 
- 
    
  
  § 36.304(c)(2)
  (2) Second, a public accommodation should take measures to provide access to those areas of a place of public accommodation where goods and services are made available to the public.... 
- Stabila, Inc. Magnetic Tech Digital Electronic Level Type 96M-2
- 
    
  
  Abstract
  ABSTRACT This pilot study conducted human subject testing and objective measures of firmness and stability on nine types of exterior surfaces as part of Phase II of the Accessible Exterior... 
- 
    
  
  2013 & 2016 CBC Answer
  X3 measurement has no code basis. Both X1 and X2 measurement are acceptable if minimum width of 108 inches are achieved.... 
- 
    
  
  Sec.36.304(d)(1)
  1) Except as provided in paragraph (d)(2) of this section, measures taken to comply with the barrier removal requirements of this section shall comply with the applicable requirements for... 
- 
    
  
  TEST NO. 1 – INDIVIDUAL BUILDING TEST
  The slopes of the undisturbed site measured between the planned entrance and all vehicular or pedestrian arrival points within 50 feet (15 240 mm) of the planned entrance exceed 15 percent... 
- 
    
  
  D. Election Day Compliance Review
  In the materials provided to each in-precinct Election Coordinator, the Board will include a checklist of the temporary measures to be implemented during the voting period at each... 
