Telephone Terminal Equipment Handset Magnetic Measurement Procedures and Performance Requirements, (March 2007), IBR proposed for Section 410.4.2....
Search Results "Measuring Technique"
Commonly Searched Documents
-
C102.8.2 TIA 1083
-
1018.5 Obstacles
This section requires obstacles to not exceed 1/2 inch in height measured vertically to the highest point....
-
4.34.6.5(1)
(1) The sink and surrounding counter shall be mounted at a maximum height of 34 in (865 mm) above the floor, measured from the floor to the top of the counter surface, or shall be adjustable...
-
11B-405.3 Cross slope
Cross slope is measured the same way as slope is measured (i.e., the rise over the run). Advisory 11B-405.3 Cross slope....
-
11B-405.3 Cross slope
Cross slope is measured the same way as slope is measured (i.e., the rise over the run). ◼ Advisory 11B-405.3 Cross slope....
-
1018.5 Obstacles
Obstacles on beach access routes and resting intervals shall not exceed 1/2 inch (13 mm) in height measured vertically to the highest point....
-
1018.5 Obstacles
Obstacles on beach access routes and resting intervals shall not exceed 1/2 inch (13 mm) in height measured vertically to the highest point....
-
M301.4.2 Clearance Around Base
The base of the equipment shall provide a clearance 6 inches (150 mm) high minimum measured from the floor and 36 inches (915 mm) deep minimum measured from the edge of the examination surface...
-
M302.4.2 Clearance Around Base
The base of the equipment shall provide a clearance 6 inches (150 mm) high minimum measured from the floor and 36 inches (915 mm) deep minimum measured from the edge of the examination surface...
-
810.2.2 Dimensions--Modification to 810.2.2 of Appendix D to 36 CFR Part 1191
810.2.2 Dimensions--Modification to 810.2.2 of Appendix D to 36 CFR Part 1191 Bus boarding and alighting areas shall provide a clear length of 96 inches (2440 mm), measured perpendicular...
-
Tread Width
The visible trail surface measured perpendicular to the direction of travel....
-
11B-221.2.1.5 Stadium-style movie theaters
following criteria: Located within the rear 60 percent of the seats provided in the theater; or Located within the area of the theater in which the vertical viewing angles (as measured...
-
11B-809.10.7.1 Floor space
The floor space at water closets shall be 48 inches (1219 mm) wide minimum measured perpendicular to the side wall....
-
Introduction
Data collection included 3 dimensional measurements of approximately 90 points located on the body and device....
-
What surface characteristics are required of an accessible route?
No standards or methods of measurement are specified in scoping or technical provisions, although the Appendix to ADAAG contains advisory recommendations for slip resistance values derived...
-
Transfer Surface Height (M301.2.1 and M302.2.1)
M301.2.1 and M302.2.1 would require the height of the transfer surface during patient transfer to be 17 inches minimum and 19 inches maximum measured from the floor to the top of the transfer...
-
D. Election Day Compliance Review
In the materials provided to each Judge of Election for Election Day, the County will include a checklist of the temporary measures to be implemented on Election Day at each polling...
-
2.2.5 Grip Strength
2.2.5 Grip Strength Four types of grip strength measurements for the dominant hand were assessed....
-
604.8.1.1 Size
Wheelchair accessible compartments shall be 60 inches (1525 mm) wide minimum measured perpendicular to the side wall, and 56 inches (1420 mm) deep minimum for wall hung water closets and...
-
604.8.1.1 Size
Wheelchair accessible compartments shall be 60 inches (1525 mm) wide minimum measured perpendicular to the side wall, and 56 inches (1420 mm) deep minimum for wall hung water closets and...
-
604.8.1.1 Size
Wheelchair accessible compartments shall be 60 inches (1525 mm) wide minimum measured perpendicular to the side wall, and 56 inches (1420 mm) deep minimum for wall hung water closets and...
-
11B-604.8.1.1 Size
Wheelchair accessible compartments shall be 60 inches (1524 mm) wide minimum measured perpendicular to the side wall, and 56 inches (1422 mm) deep minimum for wall hung water closets and...
-
D. Election Day Compliance Review
In the materials provided to each Election Judge for Election Day, the County will include a checklist of the temporary measures to be implemented on Election Day at each...
-
703.3.1 Dimensions and Capitalization
Table 703.3.1 Braille Dimensions MEASUREMENT RANGE MINIMUM IN INCHES MAXIMUM IN INCHES Dot base diameter 0.059...