Where only the minimum 50 percent of the holes are accessible, an accessible route from the last accessible hole to the course exit or entrance must not require travel back through other...
Search Results "Minimum Dimension"
-
11B-239.3 Miniature golf course configuration
-
ADA Title IV: Telecommunications Relay Services
The Federal Communications Commission (FCC) has set minimum standards for TRS services. Title IV also requires closed captioning of Federally funded public service announcements....
-
11B-307.2 Protrusion limits
For example, awnings and their supporting structures cannot reduce the minimum required vertical clearance....
-
11B-1009.3.3 Handrails
The clear width between required handrails shall be 33 inches (838 mm) minimum and 38 inches (965 mm) maximum. Exceptions: 1. ...
-
11B-221.4 Designated aisle seats
Only when all seats on Aisle A would not meet the five percent minimum would seats on Aisle B be designated....
-
F227.2 Check-Out Aisles
Table F227.2 Check-Out Aisles Number of Check-Out Aisles of Each Function Minimum Number of Check-Out Aisles of Each Function Required to Comply with 904.3...
-
610.3 Shower Compartment Seats
The top of the seat shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum above the bathroom finish floor. Seats shall comply with 610.3.1 or 610.3.2....
-
F239.3 Miniature Golf Course Configuration
Where only the minimum 50 percent of the holes are accessible, an accessible route from the last accessible hole to the course exit or entrance must not require travel back through other...
-
Swimming Pools
Swimming Pools Large pools must have a minimum of two accessible means of entry. A large pool is defined as any pool with over 300 linear feet of pool wall. ...
-
Accessible Routes
The accessible route must comply with ADAAG provisions for the location, width (minimum of 36 inches), passing space, head room, surface, slope (maximum of 1:12 or 8.33%), changes in level...
-
Certification.
The current title III regulation provides that state or local governments may apply to the Department for certification that state laws or local building codes comply with or exceed the minimum...
-
Reliance on Preamble to Guidelines
The Fair Housing Accessibility Guidelines are -- as the name indicates -- only guidelines, not regulations or minimum requirements....
-
C. Accessibility Within Toilet Rooms
Is there an area within the toilet room where a person who uses a wheelchair or mobility device can turn around - either a minimum 60-inch diameter circle or a “T”-shaped turn area?...
-
11B-606.3 Height
In residential dwelling unit kitchens, sinks that are adjustable to variable heights, 29 inches (737 mm) minimum and 36 inches (914 mm) maximum, shall be permitted where rough-in plumbing...
-
A4.31.9 Text Telephones
telephone which is not a single integrated text telephone pay phone unit will require a shelf large enough (10 in (255mm) wide by 10 in (255 mm) deep with a 6 in (150 mm) vertical clearance minimum...
-
7.2.2.1 Determining Impracticability
The minimum trail width is 12 inches (305 millimeters) or less for a distance of at least 20 feet (6100 mm). Limiting Factor 4. ...
-
1017.5 Tread Obstacles
Where possible, tread obstacles that cross the full width of the trail tread should be separated by 48 inches minimum so individuals who use wheeled mobility devices can cross the obstacle...
-
Legal Authority and Purpose
for the design, construction, and alteration of facilities covered by the Architectural Barriers Act.2 We are required by section 502 of the Rehabilitation Act to establish and maintain minimum...
-
Pictograms and Symbols of Accessibility [ADA Standards §216.2 , §703.6, §703.7]
directional signs must comply with requirements for finish and contrast but are not required to include the verbal equivalent in raised and braille characters or to be located on a 6” minimum...
-
Location [§208.3]
The minimum number must still be determined separately for each parking facility....
-
11B-404.2.4.2 Doorways without doors or gates, sliding doors, and folding doors
TABLE 11B-404.2.4.2 MANEUVERING CLEARANCES AT DOORWAYS WITHOUT DOORS OR GATES, MANUAL SLIDING DOORS, AND MANUAL FOLDING DOORS Minimum Maneuvering Clearance...
-
11B-505.10.3 Bottom extension at stairs
The horizontal extension of a handrail shall be 12 inches (305 mm) long minimum and a height equal to that of the sloping portion of the handrail as measured above the stair nosings....
-
11B-606.3 Height
In residential dwelling unit kitchens, sinks that are adjustable to variable heights, 29 inches (737 mm) minimum and 36 inches (914 mm) maximum, shall be permitted where rough-in plumbing...