Other recommendations from this study include: a minimum 32 inch clearance for each leaf when hinged out for emergency use safety systems such as motion detectors within...
Search Results "Minimum Dimension"
Commonly Searched Documents
-
Automated Revolving Doors
-
Trail Facilities
As explained in "Camp Shelters" of this guidebook, this can be accomplished by ensuring the camp shelter floor is 17 inches (430 millimeters) minimum to 19 inches (485 millimeters) maximum...
-
Reporting
The Report shall include, at a minimum, a description of the nature of the allegation, the name and contact information of the individual bringing the allegation, and documents in the Village's...
-
Reporting
The Report shall include, at a minimum, a description of the nature of the allegation, the name and contact information of the individual bringing the allegation, and documents in the City...
-
Reporting
The Report shall include, at a minimum, a description of the nature of the allegation, the name and contact information of the individual bringing the allegation, and documents in the City...
-
Reporting
The Report shall include, at a minimum, a description of the nature of the allegation, the name and contact information of the individual bringing the allegation, and documents in the City's...
-
A. Section 504
regulation, the design, construction, or alteration of buildings in conformance with UFAS is deemed to be in compliance with the accessibility requirements of Section 504.6 UFAS is based on the minimum...
-
Employee Work Areas [§203.9]
At a minimum, areas used only by employees as work areas must meet requirements for: access to approach, entry, and exit the work area (§203.9) accessible means of egress...
-
Existing Elevators (Alterations)
For example, if a car operating panel is upgraded, at a minimum the new panel must comply. Other elements of a car that are not altered are not required to comply....
-
Other relevant federal rules and guidance documents
DOJ also indicated its intention to include in its ADA regulations scoping requirements that specify the minimum number of types of accessible medical equipment required in different types...
-
TEST NO. 2 – SITE ANALYSIS TEST
The minimum percentage of ground floor units required on an accessible route shall equal the percentage of the total buildable area (not restricted-use areas) of the undisturbed site with...
-
11B-702.1 General
except that the maximum allowable sound level of audible notification appliances complying with section 4-3.2.1 of NFPA 72 (1999 edition) shall have a sound level no more than 110 dB at the minimum...
-
11B-206.2.7 Press boxes
An accessible route shall not be required to free-standing press boxes that are elevated above grade 12 feet (3660 mm) minimum provided that the aggregate area of all press boxes is 500...
-
11B-404.2.4.1 Swinging doors and gates
TABLE 11B-404.2.4.1 MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS AND GATES Type of Use Minimum Maneuvering Clearance Approach...
-
10) Assembly areas
The minimum number of receivers must be equal to four percent of the total number of seats, but never less than two (§4.1.3(19)(b))....
-
TEST NO. 2 – SITE ANALYSIS TEST
The minimum percentage of ground floor units required on an accessible route shall equal the percentage of the total buildable area (not restricted-use areas) of the undisturbed site with...
-
11B-206.2.7 Press boxes
An accessible route shall not be required to free-standing press boxes that are elevated above grade 12 feet (3660 mm) minimum provided that the aggregate area of all press boxes is 500...
-
11B-404.2.4.1 Swinging doors and gates
TABLE 11B-404.2.4.1 MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS AND GATES TYPE OF USE MINIMUM MANEUVERING CLEARANCE Approach...
-
11B-702.1 General
except that the maximum allowable sound level of audible notification appliances complying with section 4-3.2.1 of NFPA 72 (1999 edition) shall have a sound level no more than 110 dB at the minimum...
-
11B-608.5.3 Alternate roll-in type shower compartments
In alternate roll-in type shower compartments, the controls, faucets, and shower spray unit shall be located on the side wall of the compartment adjacent to the 16 inches (406 mm) minimum...
-
Fulton County - Diversity and Civil Rights Compliance Officer II
Minimum Qualifications: Bachelor's Degree in Public Administration, Business Administration, Human Resources, Construction Management/Architecture or a related field required; five years...
-
B. The ADA Standards for Accessible Design
They establish the minimum scoping and technical requirements for a facility or part thereof to be “readily accessible to and usable by individuals with disabilities.” 2010 Standards, Overview...
-
3.3.16 Door Use
One interesting finding, however, was that “Closing” trials were more likely to be rated as “minimum effort” for door 2 than door 1, despite door 2 being 215 mm (8.5 in.) wider than door...
- citEcar ADA Electric Shuttle 11P 1WC