The deck surface between the centerline of the seat and the pool edge shall have a slope not steeper than 1:48....
Search Results "Side Transfer Surface"
Commonly Searched Documents
-
11B-1009.2.2 Seat location
- Willoughby Industries 2250 AquaDeck Lavatory Deck Radiused Front
-
Background
A surface that might be firm and stable in one region of the country may be not firm and not stable in another; a surface that may be firm and stable in July may be not firm and not stable...
-
608.2.2 Standard Roll-In Type Shower Compartments
Standard roll-in type shower compartments shall be 30 inches (760 mm) wide minimum by 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides...
-
11B-502.6.4.1
The centerline of the International Symbol of Accessibility shall be a maximum of 6 inches (152 mm) from the centerline of the parking space, its sides parallel to the length of the parking...
-
Section 5 References
Section 5 References i http://udeworld.com/analysis-of-seat-height-for-wheeled-mobility-devices ii ”The Impact of Transfer Setup on the Performance of Independent Transfers: Final...
-
Conclusion
Center Study at the University of Buffalo, New York: The Wheeled Mobility Anthropometry Project, Final Report, page 49, Figure 3-5, reference to “All Device Types*”. 3 “The Impact of Transfer...
-
604.5.2 Rear Wall
The rear wall grab bar shall be 36 inches (915 mm) long minimum and extend from the centerline of the water closet 12 inches (305 mm) minimum on one side and 24 inches (610 mm) minimum on...
-
604.8.1.4 Toe Clearance
The front partition and at least one side partition shall provide a toe clearance of 9 inches (230 mm) minimum above the finish floor and 6 inches (150 mm) deep minimum beyond the compartment-side...
-
Sample Size Estimation
Data from the maximum and minimum height transfers from protocol A were used for this analysis....
-
11B-608.5.3 Alternate roll-in type shower compartments
In alternate roll-in type shower compartments, operable parts of controls and faucets shall be installed on the side wall of the compartment adjacent to the seat wall 19 inches (483 mm)...
-
11B-608.5.3 Alternate roll-in type shower compartments
In alternate roll-in type shower compartments, operable parts of controls and faucets shall be installed on the side wall of the compartment adjacent to the seat wall 19 inches (483 mm)...
-
Four Specific Situations in which a Seating Accommodation Must be Provided
The four situations are as follows: If the passenger uses an aisle chair to access the aircraft and cannot readily transfer over a fixed aisle armrest, you must provide a seat in...
-
11B.707.7.1.1 Vertically mounted display screen
or tipped away from the viewer less than 30 degrees, the center line of the display screen and other display devices shall be no more than 52 inches (1321 mm) above the floor or ground surface...
-
11B-809.10.7.1 Floor space
The floor space at water closets shall be 48 inches (1219 mm) wide minimum measured perpendicular to the side wall....
-
Limitations
Limitations The study is limited in scope by the following: Ability to generalize findings to trails in other locations with the same surfaces applied....
-
Future Work
The devices that are on the market to measure roadway roughness are not applicable to sidewalk and pedestrian surfaces because they either use accelerometers to measure the surface profile...
-
5. Bed with clear floor space
Bed with clear floor space for a side approach next to bed....
-
Ramps
Provide handrails on each side of the ramps at the following locations:...
-
Figure M2: M301.4 Lift Compatibility
(at Diagnostic Equipment for Use by a Patient in a Supine, Prone, or Side-Lying Position)...
-
F105.2.3 ASTM
ASTM F 1292-99 and ASTM F 1292-04 establish a uniform means to measure and compare characteristics of surfacing materials to determine whether materials provide a safe surface under and...
-
105.2.3 ASTM
ASTM F 1292-99 and ASTM F 1292-04 establish a uniform means to measure and compare characteristics of surfacing materials to determine whether materials provide a safe surface under and...
-
105.2.3 ASTM
ASTM F 1292-99 and ASTM F 1292-04 establish a uniform means to measure and compare characteristics of surfacing materials to determine whether materials provide a safe surface under and...
-
R305.2.1 Perpendicular Curb Ramps