4.21.2 Size and Clearances
Except as specified in 9.1.2, shower stall size and clear floor space shall comply with Fig. 35(a) or (b). The shower stall in Fig. 35(a) shall be 36 in by 36 in (915 mm by 915 mm)....
-
4.21.2 SIZE AND CLEARANCES
Shower stall size and clear floor space shall comply with Fig. 35(a) or (b). The shower stall in Fig. 35(a) shall be 36 in by 36 in (915 mm by 915 mm)....
-
4.21.3 SEAT
A seat shall be provided in shower stalls 36 in by 36 in (915 mm by 915 mm) and shall be as shown in Fig. 36....
-
4.21.3 Seat
A seat shall be provided in shower stalls 36 in by 36 in (915 mm by 915 mm) and shall be as shown in Fig. 36....
-
4.21.4 Grab Bars
Grab bars complying with 4.26 shall be provided as shown in Fig. 37.
-
4.21.4 GRAB BARS
Figure 37 Grab Bars at Shower Stalls...
-
4.21.5 Controls
In shower stalls 36 in by 36 in (915 mm by 915 mm), all controls, faucets, and the shower unit shall be mounted on the side wall opposite the seat....
-
4.21.5 CONTROLS
In shower stalls 36 in by 36 in (915 mm by 915 mm), all controls, faucets, and the shower unit shall be mounted on the side wall opposite the seat....
-
4.21.7 CURBS
If provided, curbs in shower stalls 36 in by 36 in (915 mm by 915 mm) shall be no higher than 1/2 in (13 mm)....
-
4.21.7 Curbs
If provided, curbs in shower stalls 36 in by 36 in (915 mm by 915 mm) shall be no higher than 1/2 in (13 mm)....
-
Shower Stalls [4.21]
Often a shower chair, a mobility aid more suitable for bathing than a typical wheelchair, is used with roll-in showers....
-
ROLL-IN SHOWER STALLS
-
Size and Clearances [4.21.2]
Recommendation:Placing them beyond this space however can provide easier maneuvering to and from the shower. When a seat is provided in a roll-in shower, it must be a folding seat....
-
Example of a Single-User Bathroom (with Roll-in Shower)
Example of a Single-User Bathroom (with Roll-in Shower) Clear space required at any fixture can overlap required clear floor spaces, turning space, and door maneuvering space....
-
4.34.5.5 SHOWERS
If a shower is provided, it shall have the following features:...
-
608.4 Seats (Exception)
608.4 Seats (Exception) This section requires a folding or non-folding seat to be provided in transfer type shower compartments....
-
Minimum Number [9.1.2 and 9.1.3]
Rooms with combination roll-in/transfer showers are required in transient lodging facilities with more than 50 rooms....
-
608.2.2 Standard Roll-In Type Shower Compartments
Standard roll-in type shower compartments shall be 30 inches (760 mm) wide minimum by 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides...
-
608.2.2.1 Clearance
A 30 inch (760 mm) wide minimum by 60 inch (1525 mm) long minimum clearance shall be provided adjacent to the open face of the shower compartment....
-
608.3.2 Standard Roll-In Type Shower Compartments
Where a seat is provided in standard roll-in type shower compartments, grab bars shall be provided on the back wall and the side wall opposite the seat....