Women's Spa and Fitness Center Locker Room (1) Defendants will convert the Swiss shower of the current Royal Suite spa massage treatment room to a roll-in shower, pursuant to 2010 Standards...
Search Results "Roll-In Shower"
Commonly Searched Documents
-
G. Women's Spa and Fitness Center Locker Room
-
11B-608.2.1 Transfer type shower compartments
mm) wide minimum entry on the face of the shower compartment....
-
9.1.2 Accessible Units, Sleeping Rooms, and Suites
In addition, in hotels, of 50 or more sleeping rooms or suites, additional accessible sleeping rooms or suites that include a roll-in shower shall also be provided in conformance with the...
-
11B-608.2 Size and clearances for shower compartments
Shower compartments shall have sizes and clearances complying with Section 11B-608.2....
-
Plan 2B: 13-Foot Wide Accessible Guest Room
Features include an alternate roll-in shower with a seat, comparable vanity, wardrobe, and door connecting to adjacent guest room. Furnishings include two beds. ...
-
9.5.2(2)(c)
turning space complying with 4.2.3, one water closet complying with 4.16, one lavatory complying with 4.19 and the door shall have a privacy latch; and, if provided, at least one tub or shower...
- Figure 608.2.2 Standard Roll-In Type Shower Compartment Size and Clearance – Drawing from the U.S. Access Board
-
11B-608.3.1 Transfer type shower compartments
In transfer type compartments, grab bars shall be provided across the control wall and back wall to a point 18 inches (457 mm) from the control wall.
-
8. Shower Curbs
Are the roll-in showers free of curbs or lips at the shower floor that would impede wheelchair approach and transfer onto the folding shower seat?...
-
11B-608.5 Controls
Controls, faucets, and shower spray units shall comply with Section 11B-309.4. Controls and faucets shall allow the user to close and open the water supply....
-
1014.2.2 Roll-in Access
Where roll-in access is provided at the entrance to a camp shelter, the entrance shall comply with 1014.2.2....
-
1014.2.2 Roll-in Access
Where roll-in access is provided at the entrance to a camp shelter, the entrance shall comply with 1014.2.2....
-
1607.9.2 Grab bars, shower seats and accessible benches
Grab bars, shower seats and accessible benches shall be designed to resist a single concentrated load of 250 pounds (1.11 kN) applied in any direction at any point on the grab bar, shower...
-
1607A.9.2 Grab bars, shower seats and accessible benches
Grab bars, shower seats and accessible benches shall be designed to resist a single concentrated load of 250 pounds (1.11 kN) applied in any direction at any point on the grab bar, shower...
- Figure 608.3.2 Grab Bars for Standard Roll-In Type Showers – Drawing from the U.S. Access Board
- Willoughby Industries WRS-BF-FA-2HD Front Mounted Recessed Shower Panel 2 Fixed Shower Heads
- Healthcraft Invisia ADA Serenaseat™ Folding Shower Seat
-
Shower Threshold
This provision applied to roll-in showers and to transfer showers....
- Figure 608.2.3 Alternate Roll-In Type Shower Compartment Size and Clearance – Drawing from the U.S. Access Board
-
608 Shower Compartments
Section 608 addresses transfer showers and roll-in showers and provides specifications for size and clearances, grab bars, seats, operable parts, shower spray units, thresholds, and enclosures...
- Willoughby Industries WRS-BF-FA Front Mounted Recessed Shower Panel With Hand Held Flexshower Head
-
11B-608 Shower compartments
[See subsections ...]
-
1014.2.2 Roll-in Access
Where roll-in access is provided, this section requires a level or sloped entry route complying with the technical requirements for outdoor recreation access routes in 1016 or trails in...
-
Minimum Number [9.1.2 and 9.1.3]
Rooms with combination roll-in/transfer showers are required in transient lodging facilities with more than 50 rooms....