The first section provides recommendations on best practices for physical accessibility and customer service that go above and beyond the minimum requirements contained within the 2010 Americans...
Search Results "Minimum Dimension"
Commonly Searched Documents
-
Introduction
-
Requirements for Certifying that the State has an ADA Transition Plan that is Consistent with the Regulations
The Division can use the Federal approval of the STIP as an opportunity to discuss the ADA transition plan’s consistency with the minimum transition plan attributes....
-
Proposed requirement for cell alterations. (Section-by-Section Analysis)
alterations are originally planned), provided that: Each substitute cell is located within the same facility; is integrated with other cells to the maximum extent feasible; and has, at a minimum...
-
National Accessibility Code
The Department notes that the ANSI Standard also serves as the design basis for the Uniform Federal Accessibility Standards (UFAS), the Minimum Guidelines and Requirements for Accessible...
-
J. Bedside Clearance
[ADA Stds. 9.2.2(1)] Yes __ No __ N/A __ Comments: _____________________________________ ...in accessible guestrooms with two beds next to one another, is there a minimum of 36" between...
-
The National Highway Traffic Safety Administration’s (NHTSA) motor vehicle safety regulations require that a wheelchair lift be tested to withstand a 600-pound load. If the manufacturer states that the design load is 800 pounds, can the transportation operator limit actual use to 600 pounds for safety reasons?
The 600-pound test required under NHTSA’s Federal Motor Vehicle Safety Standards (FMVSS) represents the minimum design load specified under 49 CFR Part 38....
-
H29
Accessible Shower Stall Minimum Size and Clearances Accessible Shower Stall Grab Bars and Seat, Shower, and Control Area...
-
702.1 General
except that the maximum allowable sound level of audible notification appliances complying with section 4-3.2.1 of NFPA 72 (1999 edition) shall have a sound level no more than 110 dB at the minimum...
-
233.3.4 Alterations
accessible route to a residential dwelling unit, the entity shall be permitted to alter or construct a comparable residential dwelling unit to comply with 809.2 through 809.4 provided that the minimum...
-
1002.4.4.2 Side Entry
For example, where a 42 inch (1065 mm) opening is provided, a minimum clear space of 60 inches (1525 mm) in length and 36 inches (915mm) in depth is needed to ensure adequate space for maneuvering...
-
11B-411.2.2.2 Verbal identification
The verbal annunciator shall have a frequency of 300 Hz minimum and 3000 Hz maximum....
-
11B-221.2.1.1 General seating
TABLE 11B-221.2.1.1 NUMBER OF WHEELCHAIR SPACES IN ASSEMBLY AREAS NUMBER OF SEATS MINIMUM NUMBER OF REQUIRED WHEELCHAIR SPACES...
-
1009.3.3 Handrails
The clear width between required handrails shall be 33 inches (840 mm) minimum and 38 inches (965 mm) maximum. EXCEPTIONS: 1....
-
1132A.9 Smooth surface
Tempered glass doors without stiles and having a bottom rail or shoe with the top leading edge tapered at 60 degrees minimum from the horizontal....
-
Grab Bars [4.16.4]
It must be 36 inches long minimum, installed with one end space a maximum of 6 inches from the side wall....
-
Passenger Loading Zones [4.6.6]
Aisles must be at least 5 feet wide, although a wider aisle (8 feet wide minimum) is helpful at zones that serve transit vehicles with lifts or ramps....
-
4.7.10 Diagonal Curb Ramps
The bottom of diagonal curb ramps shall have 48 in (1220 mm) minimum clear space as shown in Fig. 15(c) and (d)....
-
Classes of Sleeping Accommodations [9.1.4]
However, where the different classes or types of sleeping accommodations is greater than the minimum number of rooms required to be accessible by the table, this does not mandate an increase...
-
4.1.3(19)(b)
The minimum number of receivers to be provided shall be equal to 4 percent of the total number of seats, but in no case less than two....
-
Edge Protection
Recommendation: At narrow routes in particular, consider maintenance of adjacent surfaces as raised or flush or wider route widths in consideration of minimum maneuvering and passage requirements...
-
Forward Reach [4.2.5]
This is important at lavatories and other plumbed futures where pipes and enclosures can limit how far one can pull up (17 inches minimum and 19 inches maximum)....