Hand operated flush controls shall comply with Section 11B-309 except that the flush control shall be mounted at a maximum height of 44 inches (1118 mm) above the finish floor. ...
Search Results "Floor Designation"
-
11B-605.4 Flush controls
-
11B-604.9.6 Dispensers
The outlet of the dispenser shall be 14 inches (356 mm) minimum and 19 inches (483 mm) maximum above the finish floor....
-
11B-611.4 Height
Top loading machines shall have the door to the laundry compartment located 36 inches (914 mm) maximum above the finish floor....
-
611.4 Height
Top loading machines shall have the door to the laundry compartment located 36 inches (915 mm) maximum above the finish floor....
-
410 Platform Lifts
Section 410 provides requirements for platform lifts and addresses floor surfaces, clear floor space, operable parts, and doors and gates....
-
Main Lobby
The 40 1/2" height of the main ticket counter exceeds the maximum allowable height of 36" above the finished floor. See Standards § 7.2(1). j....
-
Accessible Route
Interior accessible routes may include corridors, floors, ramps, elevators, lifts, and clear floor space at fixtures....
-
Scoping [4.1.3(10)]
Instead it requires access based on the number provided on each floor so that half (50%) are accessible to people who use wheelchairs....
-
Dispersion
For example, if a floor is occupied by separate tenancies, both types of units should be dispersed to serve occupants of each tenancy....
-
4.2.6* SIDE REACH
If the clear floor space allows parallel approach by a person in a wheelchair, the maximum high side reach allowed shall be 54 in (1370 mm) and the low side reach shall be no less than 9...
-
III-7.5140 Drinking fountains
Where there is only one drinking fountain on a floor, it must be accessible both to individuals who use wheelchairs and to those who have difficulty bending or stooping (for example, by...
-
11B-106.5 Defined terms
PIER BOAT LAUNCH RAMP BOAT SLIP BOTTLE FILLING STATION BUILDING BUILDING OFFICIAL CATCH POOL CCR CHARACTERS CHILDREN’S USE CIRCULATION PATH CLEAR CLEAR FLOOR...
-
214 Washing Machines and Clothes Dryers
1991 Standards for Accessible Design 2010 Standards for Accessible Design What’s New/Different New...
-
Van Accessible Signage
spaces over those designed to accommodate vans....
-
C. Toilet Rooms:
For any inaccessible suite toilet room and multi-user toilet room, PSE shall provide directional signage indicating the location of the designated accessible toilet rooms on the same level...
-
Accessible Rides
Accessible Rides Each newly constructed or newly designed amusement ride must provide at least one wheelchair space, or at least one ride seat designed for transfer, or a transfer device...
- Florestone 35-62H Barrier-Free Shower
- Federal Elevator Carelift Wheelchair Lift
-
Section 35.151(e) Social service center establishments
UFAS is currently the design standard for new construction and alterations for entities subject to section 504....
-
Section 35.151(e) Social service center establishments (Section-by-Section Analysis)
UFAS is currently the design standard for new construction and alterations for entities subject to section 504....
-
1134A.6, Item 4
Grab bar reinforcement shall be installed continuous in the walls of showers 32 inches to 38 inches (813 mm to 965 mm) above the floor....
-
4.7.1 General
In alterations, where a condition for exception in section 1.1 prohibits full compliance with a specific requirement for clear floor or ground space surface, slope, size, or location, the...
-
1134A.6, Item 4
Grab bar reinforcement shall be installed continuous in the walls of showers 32 inches to 38 inches (813 mm to 965 mm) above the floor....
-
11B-809.10.6.4 Reinforcement for grab bars
grabs bars shall comply with the following: Continuous reinforcement shall be installed in the walls of showers 30 inches (762 mm) maximum to 38 inches (965 mm) minimum above the finish floor...