In addition, the non-ameliorative effects of mitigating measures, such as negative side effects of medication or burdens associated with following a particular treatment regimen, may be...
Search Results "Latch Side Clearance"
Commonly Searched Documents
-
§ 35.108(d)(3)(ii)
-
11B-810.6.3 Station names
Signs shall be clearly visible and within the sight lines of standing and sitting passengers from within the vehicle on both sides when not obstructed by another vehicle....
-
IV.B.2.
width-to-height ratio between 3:5 and 1:1 and a stroke width-to-height ratio between 1:5 and 1:10, with a minimum character height (using an upper case “X”) of 1 inch for signs on the boarding side...
-
11B-809.10.7.1 Floor space
The floor space at water closets shall be 48 inches (1219 mm) wide minimum measured perpendicular to the side wall....
-
Expert Report of James L.E. Terry, Evan Terry Associates, LLC (August 9, 2018)
Sidewalks & Walkways: The ramp on the route to the building has a vertical drop-off on at least one side and no edge protection is provided (1991 ADA Stds 4.8.7; 2010 ADA Stds 405.9)...
-
Re: Lavatories Adjacent to Partitions
I would add that the California text does not specifically require a 'clearance' related to that 18" that we would theoretically be obligated to keep clear....
-
Door and Gate Surfaces: ADA Standard Section 404.2.10
Section 404.2.10 covers the current ADA Standards for door and gate surfaces on manual doors and gates.
-
1010.2.13.1 Delayed egress locking system
An attempt to egress shall initiate an irreversible process that shall allow such egress in not more than 15 seconds when a physical effort to exit is applied to the egress side door hardware...
-
11B-404.2.10 Door and gate surfaces
Swinging door and gate surfaces within 10 inches (254 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door...
- Magnetic Switch (BE9023)
-
Toilet and Bathing Rooms
requirements which will permit a small toilet room with two water closets or one water closet and one urinal to be considered a single-user toilet room provided that the room has a privacy latch...
- Landscape Forms Inc. Gretchen Bench
-
Floor Naming and Numbering
This is a little abstract one, but if you look at those elevator buttons, whether you’re in a building in San Francisco and you come in on the east side of the building and it’s Floor Level...
-
D) Curb Ramps at Intersections
This type of curb ramp has flared sides and must be used when pedestrians may enter or exit the curb ramp from the side....
-
2. Typical Issues for Individuals Who Are Blind or Have Low Vision
Typical Issues for Individuals Who Are Blind or Have Low Vision Objects that are wall mounted, that project into a pedestrian route from the side, or that are overhead can be hazards...
-
11B-403.5.1 Clear width
The clear width for aisles shall be 36 inches (914 mm) minimum if serving elements on only one side, and 44 inches (1118 mm) minimum if serving elements on both sides. 5. ...
-
IBC Comparison
Justice's Standards for Accessible Design* (column 2), which are based on the original ADA Accessibility Guidelines, and the International Building Code** (column 3) are reordered for side-by-side...
-
Part 2. Typical Issues for Voters Who Are Blind or Have Low Vision
Typical Issues for Voters Who Are Blind or Have Low Vision Objects that are wall-mounted, that project into a pedestrian route from the side, or that are overhead must be located so that...
-
11B-705.1.2.3 Islands or cut-through medians
pedestrian islands or cut-through medians shall be 36 inches (914 mm) minimum in depth extending the full width of the pedestrian path or cut-through less 2 inches (51 mm) maximum on each side...
-
Overlapping Clear Floor Space
The Board has clarified that accessible lavatories are permitted to overlap clear floor space "opposite the shower compartment side where shower controls are positioned or where a seat is...
-
11B-406.5.12 Detectable warnings
The detectable warning shall extend the full width of the curb ramp (exclusive of flared sides) and shall extend either the full depth of the curb ramp or 24 inches (610 mm) deep minimum...
-
M303.2.6 Edge Protection (Section-by-Section Analysis)
requires platforms with wheelchair spaces that are raised more than 1½ inches in height to provide a minimum 2-inch-high edge protection, measured from the surface of the platform, on each side...
-
Detailed Age Demographics
For phase 2 there is a small gap in the distribution around 25-35 years old causing the distribution on either side to be greater (Figure D2). Table D2....
-
25.1 Q. It appears from Figure 2(c) of the Guidelines (under Requirement 5) that there is a 34 inch height requirement for kitchen counters and vanities. Is this true?
Figure 2(c) of the Guidelines is illustrating the maximum side reach range over an obstruction....