Accessible routes shall consist of one or more of the following components: walking surfaces with a running slope not steeper than 1:20, doorways, ramps, curb ramps excluding the flared sides...
Search Results "Latch Side Clearance"
Commonly Searched Documents
-
402.2 Components
-
608.3.2 Standard Roll-In Type Shower Compartments
Where a seat is provided in standard roll-in type shower compartments, grab bars shall be provided on the back wall and the side wall opposite the seat....
-
5.3.2.1 Size
The clear floor or ground space shall be 60 inches (1525 mm) wide minimum measured parallel with the back of the pit toilet, and 56 inches (1420 mm) deep minimum measured parallel to the sides...
-
5.3.2.1 Size
The clear floor or ground space shall be 60 inches (1525 mm) wide minimum measured parallel with the back of the pit toilet, and 56 inches (1420 mm) deep minimum measured parallel to the sides...
-
Curb Ramps at Intersections
Curb ramps at marked crossings must be wholly contained within the crosswalk, excluding side flares....
-
§ 38.39(b)
width-to-height ratio between 3:5 and 1:1 and a stroke width-to-height ratio between 1:5 and 1:10, with a minimum character height (using an upper case “X”) of 1 inch for signs on the boarding side...
-
11B-402.2 Components
Accessible routes shall consist of one or more of the following components: walking surfaces with a running slope not steeper than 1:20, doorways, ramps, curb ramps excluding the flared sides...
-
11B-810.6.3 Station names
Signs shall be clearly visible and within the sight lines of standing and sitting passengers from within the vehicle on both sides when not obstructed by another vehicle....
-
11B-802.1.2 Width
It should be noted that although side access to the wheelchair space is allowed, companion seating in compliance with Section 11B-802.3 must also be provided adjacent to each wheelchair...
-
11B-206.2.19 Pedestrian street crossings
The curb ramp (excluding any flared sides) or blended transition shall be contained wholly within the width of the pedestrian street crossing served....
-
3. Medical Diagnostic Equipment
the low-height specifications for transfer surfaces, and replace them with a final specification for the low-transfer-height of medical diagnostic equipment used in the supine, prone, side-lying...
- Cal-Royal CR6000 Series Digital Touch Screen Door Lock
- Allegion Falcon 1590 Series Exit Devices
- TownSteel ED1400F Grade 1 Mortise Fire Device
-
F105.2.2 ASME
that at least two flat steps be provided at the entrance and exit of every escalator and that steps on escalators be demarcated by yellow lines 2 inches wide maximum along the back and sides...
-
4.3.5.3 180-degree turn around an obstacle
When the entry and egress aisles are less than this width, the 360-degree turn clearances should be provided at the turning area....
-
Re: Service Counters
CBC 11B-904.4 does not contain any qualifying language that separates the differing requirements between the employee and customer sides of the counter because this information is contained...
- Symmetry Limited Use/Limited Application (LU/LA) Elevator
- Populas Accella Adjustable Activity / Computer Workstation
- Guardian Barrier-Free Safety Station with WideArea™ Eye/Face Wash GBF1909PCC
- Disability Network/Wayne County - Detroit, MI
-
RECOMMENDATIONS
32.7 m Vertical alignment-crest 49.8 m Recumbent bicyclists 46.7 m Refuge islands 2.5 m Bicyclists with trailers 3.0 m Signal clearance...
-
505.4 Height
Sufficient vertical clearance between upper and lower handrails, 9 inches (230 mm) minimum, should be provided to help prevent entrapment. Figure 505.4 Handrail Height...