with disabilities as follows: Exception: Certain types of privately funded multistory buildings do not require installation of an elevator to provide access above and below the first floor...
Search Results "Input Floor"
Commonly Searched Documents
-
1.9.1.2
-
902.4 Dining Surfaces and Work Surfaces for Children's Use
EXCEPTION: Dining surfaces and work surfaces that are used primarily by children 5 years and younger shall not be required to comply with 902.4 where a clear floor or ground space complying...
-
11B-604.9.5 Flush controls
Hand operated flush controls shall comply with Sections 11B-309.2 and 11B-309.4 and shall be installed 36 inches (914 mm) maximum above the finish floor....
-
608.5.1 Transfer Type Shower Compartments
compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1220 mm) maximum above the shower floor...
-
4.21.6 Shower Unit
EXCEPTION: In unmonitored facilities where vandalism is a consideration, a fixed shower head mounted at 48 in (1220 mm) above the shower floor may be used in lieu of a hand-held shower head...
-
4.21.6 SHOWER UNIT
EXCEPTION: In unmonitored facilities where vandalism is a consideration, a fixed shower head mounted at 48 in (1220 mm) above the shower floor may be used in lieu of a hand-held shower head...
-
4.2.5 FORWARD REACH
If the clear floor space only allows forward approach to an object, the maximum high forward reach allowed shall be 48 in (1220 mm) (see Fig. 5(a))....
-
11B-203.10 Raised refereeing, judging and scoring areas
An accessible route complying with Division 4 shall be provided to the ground- or floor-level entry points, where provided, of stairs, ladders or other means of reaching the raised elements...
-
11B-604.7.2 Disposal units
The disposal unit shall be located below the grab bar, with the opening of the disposal unit 19” minimum (483 mm) above the finish floor....
-
1.9.1.2 Application
with disabilities as follows: Exception: Certain types of privately funded multistory buildings do not require installation of an elevator to provide access above and below the first floor...
-
§ 38.107(a)(3)
grab bar at least 40 inches long shall be mounted on at least one side wall, with one end not more than 12 inches from the back wall, at a height between 33 inches and 36 inches above the floor...
-
11B-902.4 Dining surfaces and work surfaces for children’s use
Exception: Dining surfaces and work surfaces that are used primarily by children 5 years and younger shall not be required to comply with Section 11B-902.4 where a clear floor or ground...
-
§ 38.123(a)(3)
grab bar at least 40 inches long shall be mounted on at least one side wall, with one end not more than 12 inches from the back wall, at a height between 33 inches and 36 inches above the floor...
-
§ 38.159(c)(3) Ramp threshold
The transition from roadway or sidewalk and the transition from vehicle floor to the ramp may be vertical without edge treatment up to 1/4 inch (6.5 mm)....
-
§ 38.95(c)(3) Ramp threshold
The transition from station platform to the ramp or bridge plate and the transition from car floor to the ramp or bridge plate may be vertical without edge treatment up to 1/4 inch....
-
11B-902.4 Dining surfaces and work surfaces for children’s use
Exception: Dining surfaces and work surfaces that are used primarily by children 5 years and younger shall not be required to comply with Section 11B-902.4 where a clear floor or ground...
-
11B-604.9.5 Flush controls
Hand operated flush controls shall comply with Sections 11B-309.2 and 11B-309.4 and shall be installed 36 inches (914 mm) maximum above the finish floor....
-
11B-608.5.1 Transfer type shower compartments
compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1219 mm) maximum above the shower floor...
- Lilypad Wheelchair Scale
- Palmer Fixture iSTORM2 High Speed Hand Dryer
-
Industry Standards
621-94 (1999)e1 Standard Practice for the Use of Metric (SI) Units in Building Design and Construction ASTM E 1155-96 (2001) Standard Test Method for Determining FF Floor...
-
3. Lift Compatibility Exception
One commenter, a manufacturer, agreed that equipment designed for use with an overhead lift should be excepted, and also stated that portable floor lifts should be designed to be compatible...
-
Guest Bathrooms
The top of bathtub seats shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum above the bathroom finish floor....
-
1134A.6 Showers
The maximum slope of the shower floor shall be ½ inch (12.7 mm) per foot in any direction and shall slope to a drain....