Operable parts of such hardware shall be 34 inches (865 mm) minimum and 48 inches (1220 mm) maximum above the finish floor or ground....
Search Results "Input Floor"
Commonly Searched Documents
-
404.2.7 Door and Gate Hardware
-
4.21.3 SEAT
The seat shall be mounted 17 in to 19 in (430 mm to 485 mm) from the bathroom floor and shall extend the full depth of the stall. The seat shall be on the wall opposite the controls....
-
What types of electrical or communication receptacles are exempt because they serve a “dedicated use”?
Floor electrical receptacles are also exempt. Communication receptacles serving a dedicated use include phone jacks, data ports, network and audio-visual connections....
-
11B-306.3.4 Clearance reduction
Between 9 inches (229 mm) and 27 inches (686 mm) above the finish floor or ground, the knee clearance shall be permitted to reduce at a rate of 1 inch (25 mm) in depth for each 6 inches...
-
11B-407.2.1.1 Height
[2010 ADAS] EXCEPTION: Existing call buttons and existing keypads shall be permitted to be located at 54 inches (1370 mm) maximum above the finish floor, measured to the centerline of...
-
11B-803.6 Mirrors
Mirrors shall be installed with the bottom edge of the reflecting surface 20 inches (508 mm) maximum above the finish floor or ground....
-
11B-604.7.2 Disposal units
The disposal unit shall be located below the grab bar with the opening of the disposal unit 19 inches minimum (483 mm) above the finish floor....
-
11B-306.3.4 Clearance reduction
Between 9 inches (229 mm) and 27 inches (686 mm) above the finish floor or ground, the knee clearance shall be permitted to reduce at a rate of 1 inch (25 mm) in depth for each 6 inches...
-
11B-803.6 Mirrors
Mirrors shall be installed with the bottom edge of the reflecting surface 20 inches (508 mm) maximum above the finish floor or ground....
-
11B-407.2.1.1 Height
[2010 ADA Standards] EXCEPTION: Existing call buttons and existing keypads shall be permitted to be located at 54 inches (1370 mm) maximum above the finish floor, measured to the centerline...
-
11B-407.2.2.1 Visible and audible signals
Where in-car signals are provided, they shall be visible from the floor area adjacent to the hall call buttons. Exceptions: Reserved. Reserved....
-
11B-308.3.2 Obstructed high reach
Where a clear floor or ground space allows a parallel approach to an element and the high side reach is over an obstruction, the height of the obstruction shall be 34 inches (864 mm) maximum...
-
Notes
II The IDeA Center in its research defined wheelchair wheelbase as the distance from the center of the primary drive wheel to the center of the caster measured parallel to the floor....
-
IV. Program Access
., moving a public information office from the third floor to the first floor of a building....
-
11B-604.7 Dispensers and disposal units
The outlet of the dispenser shall be below the grab bar, 19 inches (483 mm) minimum above the finish floor and shall not be located behind grab bars....
- ASI Global Partitions Stainless Steel Toilet Partitions
- Pressalit Care Nursing bench 2000, electrically height adjustable
- Cybex Total Access Lat Pull Exercise Machine
- Good Practices of Accessible Urban Development: Making Urban Environments Inclusive and Fully Accessible to ALL
-
Section 307 Protruding Objects
This dryer protrudes more than 4" from the wall and is greater than 27" above the finish floor. Isn't this a violation of Section 307 Protruding Objects?...
- Mansfield Toilet ADA Commercial Package CP-1313
- Cybex Total Access Treadmill
-
1115B.3.2, Item 3
.|_ On the other side of the water closet, provide a minimum of 28 inches (711 mm) wide clear floor space if the water closet is adjacent to a fixture or a minimum of 32 inches (813 mm)...
-
Addendum A: List of Terms
Transfer: a transfer that can be completed without the assistance or intervention Level Transfer- A transfer where the transfer surface is at the same height as the wheelchair seat to floor...