The transition from roadway or sidewalk and the transition from vehicle floor to the ramp may be vertical without edge treatment up to 1/4 inch (6.5 mm)....
Search Results "Input Floor"
Commonly Searched Documents
-
§ 38.159(c)(3) Ramp threshold
-
§ 38.95(c)(3) Ramp threshold
The transition from station platform to the ramp or bridge plate and the transition from car floor to the ramp or bridge plate may be vertical without edge treatment up to 1/4 inch....
-
11B-902.4 Dining surfaces and work surfaces for children’s use
Exception: Dining surfaces and work surfaces that are used primarily by children 5 years and younger shall not be required to comply with Section 11B-902.4 where a clear floor or ground...
-
11B-604.9.5 Flush controls
Hand operated flush controls shall comply with Sections 11B-309.2 and 11B-309.4 and shall be installed 36 inches (914 mm) maximum above the finish floor....
-
11B-608.5.1 Transfer type shower compartments
compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1219 mm) maximum above the shower floor...
- Rebuilding Together Of the Triangle - Raleigh, NC
-
11B-404.2.9 Door and gate opening force
is 35 inches (889 mm) minimum above the floor or ground surface....
-
11B-404.2.9 Door and gate opening force
is 35 inches (889 mm) minimum above the floor or ground surface....
- Panda S.85 All Aluminum Slim Profile Lift and Slide System
- Guldmann Basic High Sling - Kids
-
4. Example: Installing Curb Ramps for Program Accessibility
The town should seek input from people with mobility disabilities regarding the other key locations where curb ramps need to be installed to provide program access. ...
-
General Preamble
Major sources This document has been prepared using input from a number of sources, including two documents from the Access Board (Telecommunications Requirements and the ADAAG)....
-
Section 610 Review.
The Office of Advocacy has advised that although the process followed by the Department was ancillary to the proposed adoption of revised ADA Standards, the steps taken to solicit public input...
-
Section 610 Review.
The Office of Advocacy has advised that although the process followed by the Department was ancillary to the proposed adoption of revised ADA Standards, the steps taken to solicit public input...
-
B. Proposed 255 Guidelines
For example, the guidelines require input, output, display, control, and mechanical functions to be accessible to individuals with disabilities....
-
Design parameter considerations
caption text and audio description with museum's exhibits and media Accessible user interface to blind and visually impaired people via "talking menus," "audible keyboard echoing" of user input...
-
Industry Standards
621-94 (1999)e1 Standard Practice for the Use of Metric (SI) Units in Building Design and Construction ASTM E 1155-96 (2001) Standard Test Method for Determining FF Floor...
-
3. Lift Compatibility Exception
One commenter, a manufacturer, agreed that equipment designed for use with an overhead lift should be excepted, and also stated that portable floor lifts should be designed to be compatible...
-
Guest Bathrooms
The top of bathtub seats shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum above the bathroom finish floor....
-
1134A.6 Showers
The maximum slope of the shower floor shall be ½ inch (12.7 mm) per foot in any direction and shall slope to a drain....
-
11B-803.6 Mirrors
Mirrors shall be installed with the bottom edge of the reflecting surface 20 inches (508 mm) maximum above the finish floor or ground....
-
Problem One (Protruding Objects)
Problem One: Objects, such as branches and ceiling-mounted televisions, over a route are lower than 80 inches above the ground or floor....
-
11B-306.3.4 Clearance reduction
Between 9 inches (229 mm) and 27 inches (686 mm) above the finish floor or ground, the knee clearance shall be permitted to reduce at a rate of 1 inch (25 mm) in depth for each 6 inches...
-
11B-407.2.1.1 Height
[2010 ADAS] EXCEPTION: Existing call buttons and existing keypads shall be permitted to be located at 54 inches (1370 mm) maximum above the finish floor, measured to the centerline...