Wheelchair spaces shall provide a clear width of 30 inches (760 mm) minimum and a clear length of 48 inches (1220 mm) minimum measured to 9 inches (230 mm) minimum above the floor surface...
Search Results "Input Floor"
-
1002.4.4.1 Width and Length
-
Elevators
The "Disco" elevator hoist way entrance lacks raised and Braille floor designations on both jambs and the elevator emergency call system does not operate without voice communication....
-
1002.4.4.1 Width and Length
Wheelchair spaces shall provide a clear width of 30 inches (760 mm) minimum and a clear length of 48 inches (1220 mm) minimum measured to 9 inches (230 mm) minimum above the floor surface...
-
T402.11 Gaps
When ramps or bridgeplates are deployed for boarding and alighting, gaps between the ramp or bridgeplate surface and floor of non-rail vehicles shall not permit passage of a sphere more...
-
2e
Is there a horizontal grab bar along each of the three shower walls at 33"-36" above the floor as shown in Figure 37(b) below?...
-
H16
Is the toilet stall at least 60 inches wide and 56 inches deep (wall mounted toilet) or 59 inches deep (floor mounted toilet)?...
-
H8
If lavatories are provided, does at least one have at least a 29 inch high clearance under the front apron with the top of the rim no more than 34 inches above the floor?...
-
11B-411.2.1.7.4 Adjacency assignment
Exception: The most adjacent elevator serving the selected floor shall be assigned by hall call consoles located outside the elevator landing....
-
11B-1002.4.4.1 Width and length
Wheelchair spaces shall provide a clear width of 30 inches (762 mm) minimum and a clear length of 48 inches (1219 mm) minimum measured to 9 inches (229 mm) minimum above the floor surface...
-
306.2.4 Additional Clearance
Space extending greater than 6 inches (150 mm) beyond the available knee clearance at 9 inches (230 mm) above the finish floor or ground shall not be considered toe clearance....
-
Water Closets [4.16]
Clear floor space requirements at a toilet not located in a stall are different from those for a toilet within a stall....
-
4.6.3 Eyepiece
telescope or periscope that is usable from a seated position for viewing each point of interest shall be positioned 43 inches (1090 mm) minimum and 51 inches (1295 mm) maximum above the floor...
-
11B-602.7 Drinking fountains for standing persons
Spout outlets of drinking fountains for standing persons shall be 38 inches (965 mm) minimum and 43 inches (1092 mm) maximum above the finish floor or ground....
-
11B-411.2.1.7.4 Adjacency assignment
Exception: The most adjacent elevator serving the selected floor shall be assigned by hall call consoles located outside the elevator landing....
-
11B-1002.4.4.1 Width and length
Wheelchair spaces shall provide a clear width of 30 inches (762 mm) minimum and a clear length of 48 inches (1219 mm) minimum measured to 9 inches (229 mm) minimum above the floor surface...
-
§ 38.81(b)
doorways with lifts, ramps or bridge plates, shall have, at all times, at least 2 foot-candles of illumination measured on the step tread or lift or ramp, when deployed at the vehicle floor...
-
11B-411.2.1.7.4 Adjacency assignment
Exception: The most adjacent elevator serving the selected floor shall be assigned by hall call consoles located outside the elevator landing....
-
11B-1002.4.4.1 Width and length
Wheelchair spaces shall provide a clear width of 30 inches (762 mm) minimum and a clear length of 48 inches (1219 mm) minimum measured to 9 inches (229 mm) minimum above the floor surface...
-
4. The assessment of risk must be based on objective medical or other evidence related to a particular individual
This may include: input from the individual with a disability; the experience of this individual in previous jobs; documentation from medical doctors, psychologists...
-
5. Edge Protection
The Access Board sought public input with question 30 in the MDE NPRM preamble, on whether there is diagnostic equipment with wheelchair spaces on raised platforms that does not provide...
-
M305.3 Standing Supports (Section-by-Section Analysis)
The Access Board sought public input in questions 39 and 40 in the MDE NPRM preamble on whether the cross section dimensions for gripping surfaces should be applied to standing supports...
-
F. Impact on small entities
The Department seeks input regarding the impact the measures being contemplated by the Department with regard to Web accessibility will have on small entities if adopted by the Department...
-
Section 36.406(c) Places of Lodging (Section-by-Section Analysis)
The Department's NPRM sought public input on this proposal....
-
2.1.1 General Description
The sequence goes as follows: audio input > amplifier > electrical current in wire loop > electromagnetic field around wire loop > induced electrical current in telecoil >...