along open-sided walking surfaces, including mezzanines, equipment platforms, aisles, stairs, ramps and landings that are located more than 30 inches (762 mm) measured vertically to the floor...
Search Results "Input Floor"
Commonly Searched Documents
-
1015.2 Where required
-
11B-404.2.11 Vision lights
gates, containing one or more glazing panels that permit viewing through the panels shall have the bottom of at least one glazed panel located 43 inches (1092 mm) maximum above the finish floor...
-
1009.8 Two-way communication
A two-way communication system complying with Sections 1009.8.1 and 1009.8.2 shall be provided at the landing serving each elevator or bank of elevators on each accessible floor that is...
-
11B-608.5.2 Standard roll-in type shower compartments
the seat 16 inches (406 mm) minimum and 27 inches (686 mm) maximum from the seat wall; and shall be located above the grab bar, but no higher than 48 inches (1219 mm) above the shower floor...
-
Best Practice Recommendations for Layout Planning
If accessible restrooms are not on the same floor, increase break times between sessions....
- Disability Network Southwest Michigan - Kalamazoo and St. Joseph, MI
- Lilypad Wheelchair Scale
- Palmer Fixture iSTORM2 High Speed Hand Dryer
-
11B-1008.4.4 Entry points and seats
Where play components require transfer to entry points or seats, the entry points or seats shall be 11 inches (279 mm) minimum and 24 inches (610 mm) maximum from the clear floor or ground...
-
Turning Space
The space may overlap the accessible route and clear floor or ground space....
-
802.1.4 Approach
Because accessible routes serving wheelchair spaces are not permitted to overlap the clear floor space at wheelchair spaces, access to any wheelchair space cannot be through another wheelchair...
-
904.4.2 Forward Approach
A clear floor or ground space complying with 305 shall be positioned for a forward approach to the counter....
-
904.4.2 Forward Approach
A clear floor or ground space complying with 305 shall be positioned for a forward approach to the counter....
-
Protruding objects and vitrines
aprons, extend bases, or add barriers below objects and vitrines that project more than 4" from walls and have their leading edges greater than 27" and less than 80" above the finished floor...
-
4.17.6 Grab Bars
Grab bars may be mounted with any desired method as long as they have a gripping surface at the locations shown and do not obstruct the required clear floor area....
-
4.30.3 Character Height
Height Above Finished Floor Minimum Character Height Suspended or Projected Overhead in compliance with 4.4.2 3 in (75mm) minimum...
-
4.17.6 GRAB BARS
Grab bars may be mounted with any desired method as long as they have a gripping surface at the locations shown and do not obstruct the required clear floor area....
-
Are accessible spaces required in temporary parking lots and in unpaved lots, such as gravel or grass lots?
parking facilities, including gravel or grass lots, parking spaces and access aisles must be marked and have firm, stable, and slip resistant surfaces as specified for accessible ground and floor...
-
11B-1008.4.4 Entry points and seats
Where play components require transfer to entry points or seats, the entry points or seats shall be 11 inches (279 mm) minimum and 24 inches (610 mm) maximum from the clear floor or ground...
-
§ 38.107(a)(4)
Controls for flush valves shall be mounted no more than 44 inches above the floor....
-
§ 38.123(a)(4)
Controls for flush valves shall be mounted no more than 44 inches above the floor....
-
§ 38.23(c)(3) Ramp threshold
The transition from roadway or sidewalk and the transition from vehicle floor to the ramp may be vertical without edge treatment up to 1/4 inch....
-
11B.707.7.1.1 Vertically mounted display screen
mounted vertically or tipped away from the viewer less than 30 degrees, the center line of the display screen and other display devices shall be no more than 52 inches (1321 mm) above the floor...
-
11B-1008.4.4 Entry points and seats
Where play components require transfer to entry points or seats, the entry points or seats shall be 11 inches (279 mm) minimum and 24 inches (610 mm) maximum from the clear floor or ground...