rear grab bar shall be permitted to be 24 inches (610 mm) long minimum, centered on the water closet, where wall space does not permit a length of 36 inches (914 mm) minimum due to the location...
Search Results "Distinct Viewing Location"
-
11B-604.5.2 Rear wall
-
11B-604.5.2 Rear wall
rear grab bar shall be permitted to be 24 inches (610 mm) long minimum, centered on the water closet, where wall space does not permit a length of 36 inches (914 mm) minimum due to the location...
-
T213 Seats
[See subsections ...]
- Figure 604.5.1 Side Wall Grab Bar at Water Closets – Drawing from the U.S. Access Board
- Access Board: Tactile Sign Location
-
604.5.1 Side Wall
The side wall grab bar shall be 42 inches (1065 mm) long minimum, located 12 inches (305 mm) maximum from the rear wall and extending 54 inches (1370 mm) minimum from the rear wall....
-
604.5.1 Side Wall
The side wall grab bar shall be 42 inches (1065 mm) long minimum, located 12 inches (305 mm) maximum from the rear wall and extending 54 inches (1370 mm) minimum from the rear wall....
-
F206.1 General
Accessible routes shall not be required where outdoor recreation access routes are provided at camping facilities in accordance with F244.5, picnic facilities in accordance with F245.4, viewing...
-
604.5.1 Side Wall
The side wall grab bar shall be 42 inches (1065 mm) long minimum, located 12 inches (305 mm) maximum from the rear wall and extending 54 inches (1370 mm) minimum from the rear wall. ...
-
§ 37.91 Wheelchair locations and food service on intercity rail trains
[See subsections ...]
-
604.5.1 Side Wall
The side wall grab bar shall be 42 inches (1065 mm) long minimum, located 12 inches (305 mm) maximum from the rear wall and extending 54 inches (1370 mm) minimum from the rear wall. ...
- Figure 703.4.2 Location of Tactile Signs at Doors – Drawing from the U.S. Access Board
- Access Board: How People with Low Vision or Blindness Approach Tactile Signs
-
703.4 Installation Height and Location
Signs with tactile characters shall comply with 703.4.
-
703.4 Installation Height and Location
Signs with tactile characters shall comply with 703.4.
-
Can accessible spaces be parallel instead of perpendicular?
The Standards do not specifically require that accessible spaces be perpendicular instead of parallel, but perpendicular parking spaces are preferred at facilities located on sites because...
-
T504 Fare Collection Devices
See 2010 NPRM, Section T502.3; see also 36 CFR 1192.33 (“Where provided, the farebox shall be located as far forward as possible[.]”)....
-
Vehicle Parking
Because new recreation site locations should be chosen carefully to ensure accessibility requirements can be met, this exception should hardly ever be taken....
-
11B-703.5.5 Character height
Viewing distance shall be measured as the horizontal distance between the character and an obstruction preventing further approach towards the sign....
-
11B-703.5.5 Character height
Viewing distance shall be measured as the horizontal distance between the character and an obstruction preventing further approach towards the sign....
-
11B-703.5.5 Character height
Viewing distance shall be measured as the horizontal distance between the character and an obstruction preventing further approach towards the sign....
-
10.3.1(4)
Such signs shall be placed in uniform locations at entrances within the transit system to the maximum extent practicable....
-
607.4.1.1 Back Wall
Two grab bars shall be installed on the back wall, one located in accordance with 609.4 and the other located 8 inches (205 mm) minimum and 10 inches (255 mm) maximum above the rim of the...
-
11B-607.4.1.1 Back wall
Two grab bars shall be installed on the back wall, one located in accordance with Section 11B-609.4 and the other located 8 inches (203 mm) minimum and 10 inches (254 mm) maximum above the...