Tactile characters on signs shall be located 48 inches (1220 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest tactile character and 60 inches...
Search Results "Distinct Viewing Location"
Commonly Searched Documents
-
703.4.1 Height Above Finish Floor or Ground
-
§ 38.23(a) General
., lift or ramp) complying with paragraph (b) or (c) of this section and sufficient clearances to permit a wheelchair or other mobility aid user to reach a securement location....
-
703.4.1 Height above Finish Floor or Ground
Tactile characters on signs shall be located 48 inches (1220 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest tactile character and 60 inches...
- Figure 703.4.1 Height of Tactile Character Above Finish Floor or Ground – Drawing from the U.S. Access Board
-
Ticket Prices and Dispersal of Wheelchair Spaces
the total number of tickets at that price level to the total number of tickets in the assembly area) shall be offered for purchase, at that price level, in a nearby or similar accessible location...
-
§ 36.406(f) Assembly areas
(f) Assembly areas. Assembly areas subject to the proposed standards shall comply with the provisions applicable to assembly areas, including, but not limited to, sections 221 and...
-
§ 36.406(f) Assembly areas
(f) Assembly areas. Assembly areas subject to this section shall comply with the provisions of the 2010 Standards applicable to assembly areas, including, but not limited to,...
-
4.17.6 Grab Bars
Grab bars may be mounted with any desired method as long as they have a gripping surface at the locations shown and do not obstruct the required clear floor area....
-
4.17.6 GRAB BARS
Grab bars may be mounted with any desired method as long as they have a gripping surface at the locations shown and do not obstruct the required clear floor area....
-
11B-208.3.2 Residential facilities
complying with Sections 11B-809.2 through 11B-809.4, and adaptable features complying with Chapter 11A, Division IV, parking spaces provided in accordance with Section 11B-208.2.3.1 shall be located...
-
11B-208.3.2 Residential facilities
complying with Sections 11B-809.2 through 11B-809.4, and adaptable features complying with Chapter 11A, Division IV, parking spaces provided in accordance with Section 11B-208.2.3.1 shall be located...
-
11B-208.3.2 Residential facilities
Sections 11B-809.2 through 11B-809.4, and adaptable features complying with Sections 11B-809.6 through 11B-809.12 parking spaces provided in accordance with Section 11B-208.2.3.1 shall be located...
- Access Board: Accessible Parking in Garages
-
6.1 Required Elements for Accessible Parking
6.1 Required Elements for Accessible Parking Parking at school facilities shall be considered accessible when the following elements are provided in compliance with the CBC...
-
4.21.3 Seat
A seat shall be provided in shower stalls 36 in by 36 in (915 mm by 915 mm) and shall be as shown in Fig. 36. The seat shall be mounted 17 in to 19 in (430 mm to 485 mm) from the...
-
4.21.3 SEAT
A seat shall be provided in shower stalls 36 in by 36 in (915 mm by 915 mm) and shall be as shown in Fig. 36. The seat shall be mounted 17 in to 19 in (430 mm to 485 mm) from the...
-
68.101(c)(5)(B) Accessible route from parking area(s)
(B) An accessible route from the parking area(s) shall comply with TAS 206 and 402.
-
Clear Deck Space
The clear deck space must be a minimum of 36 inches wide and extend forward a minimum of 48 inches from a line located 12 inches behind the rear edge of the seat....
-
Are accessible spaces required in employee parking lots?
this case, it is advisable to calculate the minimum number separately for each type of space as though they were separate parking facilities, but this is not required if they are both located...
-
604.5.2 Rear Wall
rear grab bar shall be permitted to be 24 inches (610 mm) long minimum, centered on the water closet, where wall space does not permit a length of 36 inches (915 mm) minimum due to the location...
-
604.5.2 Rear Wall
rear grab bar shall be permitted to be 24 inches (610 mm) long minimum, centered on the water closet, where wall space does not permit a length of 36 inches (915 mm) minimum due to the location...
-
604.5.2 Rear Wall
rear grab bar shall be permitted to be 24 inches (610 mm) long minimum, centered on the water closet, where wall space does not permit a length of 36 inches (915 mm) minimum due to the location...
-
604.5.2 Rear Wall
rear grab bar shall be permitted to be 24 inches (610 mm) long minimum, centered on the water closet, where wall space does not permit a length of 36 inches (915 mm) minimum due to the location...