Vertical Clearance [§307.4] Headroom clearance of at least 80” high is required along all circulation paths (except at doors and doorways where a 78” minimum clearance is permitted to...
Search Results "Minimum Dimension"
-
Vertical Clearance [§307.4]
-
11B-407.3.4 Door and signal timing
The minimum acceptable time from notification that a car is answering a call until the doors of that car start to close shall be calculated from the following equation: T = D/(1.5 ft/...
-
§ 38.57(b)
allow a route at least 32 inches wide so that at least two wheelchair or mobility aid users can enter the vehicle and position the wheelchairs or mobility aids in areas, each having a minimum...
-
1009.7.2 Separation
Exterior walls separating the exterior area of assisted rescue from the interior of the building shall have a minimum fire-resistance rating of 1 hour, rated for exposure to fire from the...
-
M305.2.7 Clearance (Section-by-Section Analysis)
Specifically, the Access Board sought input from the public in question 22, on whether transfer supports on diagnostic equipment could provide 1½ inches minimum clearance around the gripping...
-
11B-604 Water closets and toilet compartments
The rear wall grab bar shall be 36 inches (914 mm) long minimum and extend from the centerline of the water closet 12 inches (305 mm) minimum on one side and 24 inches (610 mm) minimum on...
-
6.3 Minority Reports
6.3 Minority Reports Because the Advisory Committee did not achieve consensus on the recommendation for a minimum transfer surface height standard, U.S....
-
Clear Tread Width [1017.3]
The clear tread width of trails must be a minimum of 36 inches (figure 2)....
-
5.1 Transfer Surface Height Recommendations
The height of the transfer surface during patient transfer shall be 17 inches minimum and 19 inches maximum measured from the floor to the top of the transfer surface....
-
The Roles of the Access Board and the Department of Justice
The ADA requires the Access Board to "issue minimum guidelines that shall supplement the existing Minimum Guidelines and Requirements for Accessible Design for purposes of subchapters II...
-
Horizontal Alignment
This point is represented by the coefficient of friction used in the minimum design radius equations of AASHTO....
-
11B-604.5.2 Rear wall
The rear wall grab bar shall be 36 inches (914 mm) long minimum and extend from the centerline of the water closet 12 inches (305 mm) minimum on one side and 24 inches (610 mm) minimum on...
-
11B-604.5.2 Rear wall
The rear wall grab bar shall be 36 inches (914 mm) long minimum and extend from the centerline of the water closet 12 inches (305 mm) minimum on one side and 24 inches (610 mm) minimum on...
-
New Requirements for Assistive Listening Systems (ALS)
ALSs must be capable of providing sound pressure levels of 110 dB minimum and 118 dB maximum with a dynamic volume control range of 50 dB; the signalto-noise ratio for internally generated...
-
Location and Size
The side rails are 20 inches minimum in length, 6 inches minimum in height above the table surface, and 1 inch measured horizontally from the adjacent edge of the table surface....
-
11B-604.5.1 Side wall
The side wall grab bar shall be 42 inches (1067 mm) long minimum, located 12 inches (305 mm) maximum from the rear wall and extending 54 inches (1372 mm) minimum from the rear wall with...
-
11B-604.8.1.2 Doors
Toilet compartment doors shall not swing into the minimum required compartment area....
-
11B-404.2.9 Door and gate opening force
Fire doors shall have a minimum opening force allowable by the appropriate Administrative Authority....
-
11B-404.2.9 Door and gate opening force
Fire doors shall have a minimum opening force allowable by the appropriate Administrative Authority....
-
11B-404.2.9 Door and gate opening force
Fire doors shall have a minimum opening force allowable by the appropriate Administrative Authority....
-
M305.2.2 Length (Section-by-Section Analysis)
For the general provision, the MDE Advisory Committee recommended a transfer support with a length of 15 inches minimum, that overlaps the minimum depth of the transfer surface by 80 percent...
-
II. Recommendations of Diagnostic Imaging Equipment Manufacturers on Transfer Surface Low Height
The original Notice of Proposed Rulemaking (NPRM) proposal was for a minimum height in the range of 17 to 19 inches....
-
1133A.2.1 Clear width
Kitchens shall have a minimum clear width measured between any cabinet, countertop or the face of any appliance (excluding handles and controls) that projects into the kitchen and the opposing...
-
604.9.3 Height
The height of water closets shall be 11 inches (280 mm) minimum and 17 inches (430 mm) maximum measured to the top of the seat....