Clear door openings: Door openings should provide a clear width of 32 inches (815 mm) minimum....
Search Results "Minimum Dimension"
Commonly Searched Documents
-
2. b. i. Clear door openings
-
407.12.2.1 Unobstructed Side Reach
Where the operable part is located 10 inches (255 mm) or less beyond the vertical reference plane, the operable part shall be 48 inches (1220 mm) high maximum and 15 inches (380 mm) high minimum...
-
4.28.3* Visual Alarms
Visual alarm signals shall have the following minimum photometric and location features:...
-
5.1.5 Floor Height
Where the floor at the entrance to the camp shelter is elevated above the ground surface, the floor shall be 17 (430 mm) high minimum to 19 inches (485 mm) high maximum measured from the...
-
6.3(4)
(4) Each four-bed room shall have a minimum clear floor space of 48 in (1220 mm) from the foot of the bed to the foot of the opposing bed; 36 in (915 mm) between the side of the bed and...
-
68.101(c)(5) Existing buildings
In an existing building or facility, where alterations are not planned or the planned alterations will not affect an area containing a primary function, the following minimum requirements...
-
11B-812.7 Access aisle
Access aisles shall be 60 inches (1524 mm) wide minimum and shall extend the full required length of the vehicle spaces they serve....
-
11B-1008.2.5.3.1 Handrail gripping surfaces
Handrail gripping surfaces with a circular cross section shall have an outside diameter of 0.95 inch (24 mm) minimum and 1.55 inches (39 mm) maximum....
- Behavioral Safety Products #FV600 Ligature Resistant Flush Valve Cover
- Hoyer Journey Stand-Up Lift
- Willoughby Industries Ligature-Resistant Urinal ASUW-1314-HEU-BS with Washout Flush
- Hoyer Ascend Stand-Up Lift
- Midmark 641 Barrier-Free® Power Procedures Chair
- Allegion Falcon 1990 Series Cross Bar Exit Devices
-
11B-804.2.2 U-Shaped
U-shaped kitchens enclosed on three contiguous sides, clearance between all opposing base cabinets, counter tops, appliances, or walls within kitchen work areas shall be 60 inches (1524 mm) minimum...
-
503.5 Vertical Clearance
and a vehicular route from an entrance to the passenger loading zone, and from the passenger loading zone to a vehicular exit shall provide a vertical clearance of 114 inches (2895 mm) minimum...
-
707.7.2 Characters
Characters shall be 3/16 inch (4.8 mm) high minimum based on the uppercase letter "I"....
-
11B-707.7.2 Characters
Characters shall be 3/16 inch (4.8 mm) high minimum based on the uppercase letter "I"....
-
1009.2.4 Seat Height
The height of the lift seat shall be designed to allow a stop at 16 inches (405 mm) minimum to 19 inches (485 mm) maximum measured from the deck to the top of the seat surface when in the...
-
505.10.2 Top Extension at Stairs
At the top of a stair flight, handrails shall extend horizontally above the landing for 12 inches (305 mm) minimum beginning directly above the first riser nosing....
-
707.7.2 Characters
Characters shall be 3/16 inch (4.8 mm) high minimum based on the uppercase letter "I"....
-
5.8.3.1 Breast Platform Height
The final version of the criteria must clarify that the specified height range is a minimum range of travel....
-
14.1 Q. How many resident parking spaces must be made accessible at the time of construction?
The Guidelines provide that a minimum of two percent of the parking spaces serving covered dwelling units be made accessible and located on an accessible route to wheelchair users....
-
308.2.1 Unobstructed
Where a forward reach is unobstructed, the high forward reach shall be 48 inches (1220 mm) maximum and the low forward reach shall be 15 inches (380 mm) minimum above the finish floor or...