Buttons shall be arranged in columns to the right of the keypad with a minimum horizontal spacing of 1.5 times the horizontal spacing between the numeric keys and with the same vertical...
Search Results "Minimum Dimension"
-
11B-411.2.1.4.1.1 Arrangement
-
11B-404.2.6 Doors in series and gates in series
The distance between two hinged or pivoted doors in series and gates in series shall be 48 inches (1219 mm) minimum plus the width of doors or gates swinging into the space....
-
11B-706.4 Sound pressure level
Assistive listening systems shall be capable of providing a sound pressure level of 110 dB minimum and 118 dB maximum with a dynamic range on the volume control of 50 dB....
-
11B-304.3.1 Circular space
The turning space shall be a space of 60 inches (1524 mm) diameter minimum. The space shall be permitted to include knee and toe clearance complying with Section 11B-306....
-
11B-602.7 Drinking fountains for standing persons
Spout outlets of drinking fountains for standing persons shall be 38 inches (965 mm) minimum and 43 inches (1092 mm) maximum above the finish floor or ground....
-
11B-604.5.2 Rear wall
The rear wall grab bar shall be 36 inches (914 mm) long minimum and extend from the centerline of the water closet 12 inches (305 mm) minimum on one side and 24 inches (610 mm) minimum on...
-
Shower and Sauna Doors in Transient Lodging Facilities
All saunas except for custom-made saunas are made to manufacturers’ standard dimensions....
-
Assessment Factors
Assessment Factors In deciding whether a particular type of OPDMD can be accommodated in a particular facility, the following factors must be considered: the type, size, weight, dimensions...
-
3. Terminology
E1364 or dynamically using a rolling inclinometer per Test Method E2133. 3.1.1.2 traveled surface roughness—the deviations of a surface from a true planar surface with characteristics dimensions...
-
Wheeled Mobility Anthropometry Project
seat heights of many mobility devices are above the range specified in the 2004 ADA and ABA Accessibility Guidelines for certain architectural features that involve transfers and that the dimensions...
-
Appendix 4 – References
Determination of new dimensions for universal design codes and standards with consideration of powered wheelchair and scooter users. Manitoba, CA: Universal Design Institute....
-
R302.3.2 Shared Use Paths
As proposed in the NPRM, R302.3 would require pedestrian access routes to be 4 feet wide minimum, except R302.3.1 would require pedestrian access routes within medians and pedestrian refuge...
-
Height and Clearances [4.19.2]
Height and Clearances [4.19.2] An apron clearance of at least 29 inches (minimum depth not specified) allows a person using a wheelchair to get as close as possible to the front of the...
-
Background
One-hundred and twenty adult WMD users were tested and the primary outcome measures collected were the maximum and minimum attainable vertical heights of the transfer surface, maximum gap...
-
M305.3.1.1 Horizontal Position
The length of gripping surfaces on horizontal standing supports shall be 4 inches (100 mm) minimum except for diagnostic equipment containing a wheelchair space which shall comply with M305.3.1.2...
-
409.4.6.2 Location
Control panels shall be on a side wall, 12 inches (305 mm) minimum from any adjacent wall. Figure 409.4.6.2 Location of Private Residence Elevator Control Panel...
-
703.2.8 Line Spacing
Spacing between the baselines of separate lines of raised characters within a message shall be 135 percent minimum and 170 percent maximum of the raised character height....
-
305.7.2 Parallel Approach
Alcoves shall be 60 inches (1525 mm) wide minimum where the depth exceeds 15 inches (380 mm). Figure 305.7.2 Maneuvering Clearance in an Alcove, Parallel Approach...
-
305.7.1 Forward Approach
Alcoves shall be 36 inches (915 mm) wide minimum where the depth exceeds 24 inches (610 mm). Figure 305.7.1 Maneuvering Clearance in an Alcove, Forward Approach...
-
607.4.2.2 Control End Wall
A grab bar 24 inches (610 mm) long minimum shall be installed on the control end wall at the front edge of the bathtub. [ECTCR UFAS 4.34.5.4(3), Fig. 48(a)]...
-
M305.3.2.2 Vertical Position
The height of the lowest end of the gripping surface on vertical standing supports shall be 34 inches (865 mm) minimum and 37 inches (940 mm) maximum above the standing surface....
-
1009.4.2 Height
The height of the transfer wall shall be 16 inches (405 mm) minimum and 19 inches (485 mm) maximum measured from the deck. Figure 1009.4.2 Transfer Wall Height...
-
1009.6.2 Handrails
The width between handrails shall be 20 inches (510 mm) minimum and 24 inches (610 mm) maximum. Handrail extensions required by 505.10.3 shall not be required on pool stairs....
-
703.2.8 Line Spacing
Spacing between the baselines of separate lines of raised characters within a message shall be 135 percent minimum and 170 percent maximum of the raised character height....