Access Board to promulgate regulatory standards “setting forth the minimum technical criteria for medical diagnostic equipment used in (or in conjunction with) physician's offices, clinics...
Search Results "Minimum Dimension"
Commonly Searched Documents
-
BACKGROUND
-
Review Process
If the Division Administrator and Civil Rights Specialist believe the State’s transition plan does not meet the minimum attributes, they should work with the State DOT to address the identified...
-
11B-502.6 Identification
Signs shall be 60 inches (1524 mm) minimum above the finish floor or ground surface measured to the bottom of the sign. [2010 ADAS] 502.6 Identification. ...
-
11B-502.6 Identification
Signs shall be 60 inches (1524 mm) minimum above the finish floor or ground surface measured to the bottom of the sign. [2010 ADAS] 502.6 Identification. ...
-
11B-502.6 Identification
Signs shall be 60 inches (1524 mm) minimum above the finish floor or ground surface measured to the bottom of the sign. [2010 ADA Standards] 502.6 Identification....
-
11B-703.5.9 Line spacing
Spacing between the baselines of separate lines of characters within a message shall be 135 percent minimum and 170 percent maximum of the character height. [S.H. ...
-
Lifting Capacity
Lifting Capacity Lifts must have the capability of supporting a minimum weight of 300 pounds and be capable of sustaining a static load that is at least 1.5 times the rated load....
-
803.5 Coat Hooks and Shelves
Shelves shall be 40 inches (1015 mm) minimum and 48 inches (1220 mm) maximum above the finish floor or ground....
-
5.8.1.2.2 Single Ramped Entry – Edge Protection on the Platform and Platform Sides
A 2 inch high edge protection must be provided on the back of the platform, opposite the entry ramp and a minimum 2 inch high edge protection on the sides of the platform....
-
R410.9 Character Spacing
Spacing between individual characters shall be 10 percent minimum and 35 percent maximum of character height....
-
T603.3.2 Non-Rail Vehicles with Gross Vehicle Weight Rating Less than 30,000 lbs
with a gross vehicle weight rating less than 30,000 pounds (13,608 kg), wheelchair securement systems shall restrain a force in the forward longitudinal direction of 5,000 lbf (22,000 N) minimum...
-
T405.3 Visual Contrast
The stripe shall be 1 inch (25 mm) wide minimum and shall contrast visually with the rest of the step tread or circulation path surface either light-on-dark or dark-on-light....
-
703.5.8 Character Spacing
Spacing between individual characters shall be 10 percent minimum and 35 percent maximum of character height....
-
404.2.8.1 Door Closers and Gate Closers
Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum...
-
703.5.6 Height from Finish Floor or Ground
Visual characters shall be 40 inches (1015 mm) minimum above the finish floor or ground....
-
11B-602.5 Spout location
The spout shall be located 15 inches (381 mm) minimum from the vertical support and 5 inches (127 mm) maximum from the front edge of the unit, including bumpers. ...
-
4.21.7 Curbs
Shower stalls that are 30 in by 60 in (760 mm by 1525 mm) minimum shall not have curbs....
-
Separate Tenancies
This is required even where it would increase the minimum number above the number of required exits or 50% of facility entrances....
-
Steps
ADAAG does not specify the minimum number of steps that comprise a set of "stairs." Most building codes require handrails for a certain change in level or number of steps....
-
4.7.9.3 Height
Water spouts must be 28 inches (710 mm) minimum and 36 inches (915 mm) maximum above the ground or floor....
-
Do drinking fountains pose hazards as protruding objects?
This is not required for wheelchair accessible units with no more than a 27” clearance below (the minimum required for knee clearance and the maximum recognized for cane detection)....
-
11B-705.1.2.4 Bus stops
detectable warnings are provided at bus stop boarding and alighting areas, the detectable warnings shall extend the full width of the boarding/alighting area and shall be 36 inches (914 mm) minimum...
-
§ 38.123(b)
proximity to at least one seating location for persons using mobility aids complying with §38.125(d) of this part and shall be connected to such a space by an unobstructed path having a minimum...
- Hoyer Journey Stand-Up Lift