Plan-3: Meets Both 1991 Standards and 2010 Standards 7’-0" x 5’-9" • 40.25 Square Feet This plan shows an example of a single-user toilet room that meets the minimum...
Search Results "Minimum Dimension"
Commonly Searched Documents
-
Comparison of Single-User Toilet Room Layouts: Plan 3
-
F245.2.3 Alterations and Additions
are altered or added, the requirements of F245.2 shall apply only to the picnic units that are altered or added until the number of picnic units with mobility features complies with the minimum...
-
604.3.2 Overlap
EXCEPTION: In residential dwelling units, a lavatory complying with 606 shall be permitted on the rear wall 18 inches (455 mm) minimum from the water closet centerline where the clearance...
-
Transfer Platforms
or transfer onto the play structure and leave the wheelchair or mobility device behind at ground level. 11 inches (280 mm) to 18 inches (455 mm) height of top surface Minimum...
-
407.3.4 Door and Signal Timing
The minimum acceptable time from notification that a car is answering a call or notification of the car assigned at the means for the entry of destination information until the doors of...
-
407.3.4 Door and Signal Timing
The minimum acceptable time from notification that a car is answering a call or notification of the car assigned at the means for the entry of destination information until the doors of...
-
505.4 Height
Top of gripping surfaces of handrails shall be 34 inches (865 mm) minimum and 38 inches (965 mm) maximum vertically above walking surfaces, stair nosings, and ramp surfaces....
-
604.8.1.2 Doors
comply with 404 except that if the approach is to the latch side of the compartment door, clearance between the door side of the compartment and any obstruction shall be 42 inches (1065 mm) minimum...
-
Driving Ranges
The accessible route must be a minimum of 48 inches wide. If handrails are provided, the accessible route must be a minimum of 60 inches wide....
-
704.4.1 Height
When in use, the touch surface of TTY keypads shall be 34 inches (865 mm) minimum above the finish floor....
-
5.4.5 Transfer Support Position Recommendation for M301 and M302
5.4.5 Transfer Support Position Recommendation for M301 and M302 Description: Transfer support position refers to the placement of the gripping surface within the minimum and maximum...
-
5.7.1.1 Lift Compatibility Clearance in Base for Stretchers (M301)
5.7.1.1 Lift Compatibility Clearance in Base for Stretchers (M301) The Committee recommends the equipment base provide a clearance of 39 inches wide minimum....
-
704.4.1 Height
When in use, the touch surface of TTY keypads shall be 34 inches (865 mm) minimum above the finish floor....
-
Alterations
In alterations, the minimum number is based on the total number of spaces altered or added to a lot....
-
F244.2.1 Alterations and Additions
altered or added, the requirements of F244.2 shall apply only to the camping units that are altered or added until the number of camping units with mobility features complies with the minimum...
-
F245.2.3 Alterations and Additions
are altered or added, the requirements of F245.2 shall apply only to the picnic units that are altered or added until the number of picnic units with mobility features complies with the minimum...
-
1014.2.1 Transfer Access
Where transfer access is provided, this section requires a clear ground space 36 inches minimum by 48 inches minimum positioned for a parallel approach to be provided at the entrance to...
-
Fair Labor Standards Act Section 14(c)
Fair Labor Standards Act Section 14(c) ________________________________________________________________ 6/25/1938 The Fair Labor Standards Act (FLSA) establishes a national minimum...
-
Error/Omission: Adequate maneuvering clearance is not provided at doors, including doors to accessible toilet stalls.
Minimum maneuvering clearances at doors that are not automatic or power-assisted shall be as shown in Fig. 25....
-
11B-505.4 Height
Top of gripping surfaces of handrails shall be 34 inches (864 mm) minimum and 38 inches (965 mm) maximum vertically above walking surfaces, stair nosings, and ramp surfaces....
-
11B-703.4.1 Height above finish floor or ground
Tactile characters on signs shall be located 48 inches (1219 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest Braille cells and 60 inches (1524...
-
11B-1009.5.7 Grab bars
Where a grab bar is provided on each step, the tops of gripping surfaces shall be 4 inches (102 mm) minimum and 6 inches (152 mm) maximum above each step and transfer platform....
-
11B-1009.5.7 Grab bars
Where a grab bar is provided on each step, the tops of gripping surfaces shall be 4 inches (102 mm) minimum and 6 inches (152 mm) maximum above each step and transfer platform....
-
11B-505.4 Height
Top of gripping surfaces of handrails shall be 34 inches (864 mm) minimum and 38 inches (965 mm) maximum vertically above walking surfaces, stair nosings, and ramp surfaces....