Section 409.3.2 covers the current ADA Standards for the location of private residence elevator doors.
Search Results "Floor Designation"
Commonly Searched Documents
-
Location: ADA Standard Section 409.3.2
-
Residential Dwelling Unit Communication Systems: ADA Standard Section 708.4
Communications systems between a residential dwelling unit and a site, building, or floor entrance shall comply with 708.4....
-
11B-407.4.7.1.3 Symbols
The control button for the emergency stop, alarm, door open, door close, main entry floor, and phone, shall be identified with raised symbols and Braille as shown in Table 11B-407.4.7.1.3...
-
11B-609.4 Position of grab bars
Grab bars shall be installed in a horizontal position, 33 inches (838 mm) minimum and 36 inches (914 mm) maximum above the finish floor measured to the top of the gripping surface, except...
-
11B-809.8 Doors
The floor or landing at primary entry doors, required exit doors, and secondary exit doors where a change in elevation occurs between the interior and the exterior surface of the floor or...
-
Height: ADA Standard Section 407.4.6.4.1
Section 407.4.6.4.1 covers the current ADA Standards for the height of the emergency controls in elevator cars.
-
11B-407.4.6.4.1 Height
Emergency control buttons shall have their centerlines 35 inches (889 mm) minimum above the finish floor....
-
Expert Report of John Rife Torkelson, theACCESSpartnership, L.P. (August 8, 2018)
Voting Area: The pedestrian route within the voting area contains a thermostat that protrudes more than 4 inches into the route and the bottom of the object is more than 27 inches above the floor...
-
EQUIVALENT FACILITATION
[DSA-AC] The use of designs, products, or technologies as alternatives to those prescribed, resulting in substantially equivalent or greater accessibility and usability....
-
Before January 26, 1992
are referred to as “pre-ADA” facilities.25 If there is an architectural barrier to accessibility in a pre-ADA facility, you may remove the barrier using the ADA Standards for Accessible Design...
- Welch Allyn Scale-Tronix® Integrated Scales
-
Section 36.404 Alterations: Elevator Exemption (Section-By-Section Analysis and Response to Comments)
As is the case with new construction, the term "shopping center or shopping mall'' only includes floor levels housing at least one sales or rental establishment, or any floor level that...
-
11B-708.4 Residential dwelling unit communication systems
Communications systems between a residential dwelling unit and a site, building, or floor entrance shall comply with Section 11B-708.4....
-
11B-809.9.5 Lower shelving
Lower shelving and/or drawer space shall be provided at a height of 48 inches (1219 mm) maximum above the finish floor....
-
11B-809.10.8.3 Cabinets
The finished floor shall extend to the wall under the lavatory....
-
11B-409.3.2 Location
Elevator car doors or gates shall be positioned at the narrow end of the clear floor spaces required by Section 11B-409.4.1....
-
Requirement 6. Reinforced walls for grab bars.
Section 100.205(c)(3)(iii) requires that covered multifamily dwellings with a building entrance on an accessible route shall be designed and constructed in such a manner that all premises...
-
II-5.5000 Historic preservation programs
An historic property is a property that is listed or eligible for listing in the National Register of Historic Places or a property designated as historic under State or local law....
-
SHOPPING CENTER (OR SHOPPING MALL)
A shopping center may include a series of buildings on a common site, connected by a common pedestrian access route on, above or below the ground floor, that is either under common ownership...
-
Vision Lights: ADA Standard Section 404.2.11
Section 404.2.11 covers the current ADA Standards for vision lights on manual doors and gates.
-
Seats: ADA Standard Section 604.4
Section 604.4 covers the current ADA Standards for the water closet seats.
-
Knee and Toe Clearance (M303.2.4)
5 inches deep maximum at 14 inches above the floor Knee Clearance 11 inches deep minimum at 9 inches above the floor, and 8 inches deep minimum at...
-
Raised Courtroom Stations Not for Members of the Public
provides that raised courtroom stations used by judges and other judicial staff do not have to provide full vertical access when first constructed or altered as long as the required clear floor...
- TOTO® CT705ELN Commercial Flushometer High Efficiency Toilet