Your patients need low-profile solutions designed to help reduce their fall risks and support wide-ranging weights....
Search Results "Floor Designation"
Commonly Searched Documents
- Welch Allyn Scale-Tronix® Integrated Scales
-
Post-Mounted Objects: ADA Standard Section 307.3
Section 307.3 covers the current ADA Standards for the protrusion limits for post-mounted objects.
-
11B-307.3 Post-mounted objects
objects mounted on posts or pylons shall overhang circulation paths 12 inches (305 mm) maximum when located 27 inches (686 mm) minimum and 80 inches (2032 mm) maximum above the finish floor...
-
M301.2.1 Transfer Surface Height
The may not be designed to adjust vertically, but some are designed to rotate to place the patient in a more vertical position needed for specific diagnostic exam needs....
-
Height: ADA Standard Section 902.3
The tops of dining surfaces and work surfaces shall be 28 inches (710 mm) minimum and 34 inches (865 mm) maximum above the finish floor or ground....
-
HALL CALL CONSOLE
[DSA-AC] An elevator call user interface exclusive to a destination-oriented elevator system that requires the user to select a destination floor prior to entering the elevator car....
-
11B-902.3 Height
The tops of dining surfaces and work surfaces shall be 28 inches (711 mm) minimum and 34 inches (864 mm) maximum above the finish floor or ground....
-
11B-809.10.7.4 Seat height
Water closet seats shall be 15 inches (381 mm) minimum and 19 inches (483 mm) maximum measured to the top of the seat above the finish floor....
- TOTO® CT705ELN Commercial Flushometer High Efficiency Toilet
-
1010.1.6 Thresholds
Thresholds at doorways shall not exceed ¾ inch (19.1 mm) in height above the finished floor or landing for sliding doors serving dwelling units or ½ inch (12.7 mm) above the finished floor...
-
11B-202 Existing buildings and facilities
The principal entrance through which most people enter the building, as designated by the building official."...
-
III-7.8400 Business and mercantile
ADAAG will be satisfied if there is one accessible counter per floor at which all purchases can be made....
-
Height: ADA Standard Section 407.3.3.1
Section 407.3.3.1 covers the current ADA Standards for the height requirements of an elevators reopening device.
-
Drinking Fountains for Standing Persons: ADA Standard Section 602.7
Section 602.7 covers the current ADA Standards for drinking fountains for standing persons.
-
Height: ADA Standard Section 1008.3.1.2
The height of transfer platforms shall be 11 inches (280 mm) minimum and 18 inches (455 mm) maximum measured to the top of the surface from the ground or floor surface....
-
11B-407.3.3.1 Height
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (127 mm) nominal and 29 inches (737 mm) nominal above the finish floor....
-
11B-1008.3.1.2 Height
The height of transfer platforms shall be 11 inches (279 mm) minimum and 18 inches (457 mm) maximum measured to the top of the surface from the ground or floor surface....
-
11B-608.10 Soap dish
Where a soap dish is provided, it shall be located on the control wall at 40 inches (1016 mm) maximum above the shower floor, and within the reach limits from the seat....
-
11B-809.10.7.5 Controls
Controls shall be mounted 44 inches (1118 mm) maximum above the finish floor. The force required to activate controls shall be 5 pounds (22.2 mm) maximum....
-
11B-602.7 Drinking fountains for standing persons
Spout outlets of drinking fountains for standing persons shall be 38 inches (965 mm) minimum and 43 inches (1092 mm) maximum above the finish floor or ground....
-
Existing Site Constraints: ADA Standard Section 206.7.5
Section 206.5.1 covers scoping requirements in the most current ADA Standards for the use of platform lifts due to existing site constraints.
-
11B-904.4.2 Forward approach
A clear floor or ground space complying with Section 11B-305 shall be positioned for a forward approach to the counter. [2010 ADA Standards] 904.4.2 Forward Approach....
-
Location: ADA Standard Section 407.4.7.1.2
Section 407.4.7.1.2 covers the current ADA Standards for the location of designations and indicators on elevator car control buttons.
-
Camp Shelters
Remember that the requirements are minimums, and the Forest Service commitment to universal design dictates that as many shelters as is practicable should meet the requirements....