The minimum acceptable time from notification that a car is answering a call until the doors of that car start to close shall be calculated from the following equation: T = D or T = D...
Search Results "Minimum Dimension"
-
4.10.7* DOOR AND SIGNAL TIMING FOR HALL CALLS
-
11B-503.5 Vertical clearance
from an entrance to the passenger drop-off and loading zone and from the passenger drop-off and loading zone to a vehicular exit shall provide a vertical clearance of 114 inches (2896 mm) minimum...
-
11B-603.4 Coat hooks, shelves and medicine cabinets
Shelves shall be located 40 inches (1016 mm) minimum and 48 inches (1219 mm) maximum above the finish floor....
-
11B-812.8.7 Location
Signs shall be 60 inches (1525 mm) minimum above the finish floor or ground surface measured to the bottom of the sign....
-
11B-904.4.2 Forward approach
A portion of the counter surface that is 36 inches (914 mm) long minimum and 34 inches (864 mm) high maximum shall be provided....
-
11B-307.3 Post-mounted objects
Free-standing objects mounted on posts or pylons shall overhang circulation paths 12 inches (305 mm) maximum when located 27 inches (686 mm) minimum and 80 inches (2032 mm) maximum above...
-
11B-812.8.7 Location
Signs shall be 60 inches (1525 mm) minimum above the finish floor or ground surface measured to the bottom of the sign....
-
11B-604.7 Dispensers and disposal units
Toilet paper dispensers shall comply with 309.4 and shall be 7 inches (180 mm) minimum and 9 inches (230 mm) maximum in front of the water closet measured to the centerline of the dispenser...
-
11B-307.3 Post-mounted objects
Free-standing objects mounted on posts or pylons shall overhang circulation paths 12 inches (305 mm) maximum when located 27 inches (686 mm) minimum and 80 inches (2032 mm) maximum above...
-
1010.1.8 Door arrangement
Space between two doors in a series shall be 48 inches (1219 mm) minimum plus the width of a door swinging into the space....
-
Passing Spaces [1016.4]
Passing spaces must be: A minimum space of 60 by 60 inches or The intersection of two ORARs that provide a T-shaped space that complies with section 304.3.2 of the ABA Standards...
-
The Roles of the Access Board and the Department of Justice
The ADA requires the Access Board to "issue minimum guidelines that shall supplement the existing Minimum Guidelines and Requirements for Accessible Design for purposes of subchapters II...
-
219.3 Receivers
Twenty-five percent minimum of receivers provided, but no fewer than two, shall be hearing-aid compatible in accordance with 706.3. EXCEPTIONS: 1....
-
1017.4 Passing Spaces
Entities should consider providing either 60 inches minimum clear tread width on trails or passing spaces at shorter intervals where the trail is heavily used or where the trail is a boardwalk...
-
11B-704.3 Volume control telephones
Public telephones required to have volume controls shall be equipped with a receive volume control that provides a gain adjustable up to 20 dB minimum....
-
2. Follow the Accessibility Standards for Play Areas
The accessibility standards are minimum standards and do not require the entire play surface area to be accessible....
-
11B-604.8.1.2 Doors
Where located in the side wall or partition, the door opening shall be farthest from the water closet and shall be 54 inches (1372 mm) minimum from the rear wall. ...
- Viking K-1600-EHFA Elevator Phone with Built-in Dialer and Digital Announcer
-
11B-1003.2.2 Boarding piers at boat launch ramps
Where the total length of the gangway or series of gangways serving as part of a required accessible route is 30 feet (9144 mm) minimum, gangways shall not be required to comply with Section...
-
11B-207.2 Platform lifts
primary power loss, platform lifts shall be provided with standby power or with self-rechargeable battery power that provides sufficient power to operate all platform lift functions for a minimum...
-
11B-1003.2.2 Boarding piers at boat launch ramps
Where the total length of the gangway or series of gangways serving as part of a required accessible route is 30 feet (9144 mm) minimum, gangways shall not be required to comply with Section...
-
11B-207.2 Platform lifts
primary power loss, platform lifts shall be provided with standby power or with self-rechargeable battery power that provides sufficient power to operate all platform lift functions for a minimum...
-
Shower and Sauna Doors in Transient Lodging Facilities
All saunas except for custom-made saunas are made to manufacturers’ standard dimensions....
-
Assessment Factors
Assessment Factors In deciding whether a particular type of OPDMD can be accommodated in a particular facility, the following factors must be considered: the type, size, weight, dimensions...