Installation Verify all rough-in dimensions prior to installation. Secure separate mounting bracket to wall....
Search Results "Minimum Dimension"
Commonly Searched Documents
- Bradley Surface Mounted, Horizontal Tank, Horizontal Valve Soap Dispenser 6542
- Bradley Soap Dispenser With ABS Plastic Valve 6563
- Bradley Security Grab Bars SA70 Series
- Viking K-1600-EHFA Elevator Phone with Built-in Dialer and Digital Announcer
-
603.4 Coat Hooks and Shelves
Shelves shall be located 40 inches (1015 mm) minimum and 48 inches (1220 mm) maximum above the finish floor. [ECTCR UFAS 4.25.3, Fig. 38]...
-
902.4.1 Clear Floor or Ground Space
Knee and toe clearance complying with 306 shall be provided, except that knee clearance 24 inches (610 mm) minimum above the finish floor or ground shall be permitted....
-
810.3 Bus Shelters
Bus shelters shall provide a minimum clear floor or ground space complying with 305 entirely within the shelter....
-
11B-404.2.8.1 Door closers and gate closers
Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum...
-
11B-703.2.8 Line spacing
Spacing between the baselines of separate lines of raised characters within a message shall be 135 percent minimum and 170 percent maximum of the raised character height. [S.H. ...
-
STEP 4
there: Number of elevated = 4 (1 triple slide, 1 interactive panel, 1 overhead curved ladder, 1 banister bars) 50% = 2 Transfer access required to 2 elevated play components as a minimum...
-
R302.3 Continuous Width
Except as provided in R302.3.1 and R302.3.2, the continuous clear width of pedestrian access routes shall be 1.2 m (4.0 ft) minimum, exclusive of the width of the curb....
-
308.2.1 Unobstructed
Where a forward reach is unobstructed, the high forward reach shall be 48 inches (1220 mm) maximum and the low forward reach shall be 15 inches (380 mm) minimum above the finish floor or...
-
602.5 Spout Location
The spout shall be located 15 inches (380 mm) minimum from the vertical support and 5 inches (125 mm) maximum from the front edge of the unit, including bumpers....
-
Weather Shelters
Weather Shelters Course weather shelters must be designed and constructed to allow a golf car to enter and exit, and have a clear floor or ground space of 60 inches by 96 inches minimum...
-
902.4.1 Clear Floor or Ground Space
Knee and toe clearance complying with 306 shall be provided, except that knee clearance 24 inches (610 mm) minimum above the finish floor or ground shall be permitted....
-
5.9.2.2 Standing Supports on Dual Ramped Entry Raised Platforms with Wheelchair Spaces
Standing supports should be located on one side of the platform, integrated into the platform and stretching the full length of the platform (40 inch minimum) for dual ramped entry raised...
-
407.8.3.1 Unobstructed Forward Reach
leading edge of the maximum protrusion within the length of the vertical reference plane of the ICT, the operable part shall be 48 inches (1220 mm) high maximum and 15 inches (380 mm) high minimum...
-
602.5 Spout Location
The spout shall be located 15 inches (380 mm) minimum from the vertical support and 5 inches (125 mm) maximum from the front edge of the unit, including bumpers....
-
1009.6.1 Pool Stairs
EXCEPTION: Pool step riser heights shall not be required to be 4 inches (100 mm) high minimum and 7 inches (180 mm) high maximum provided that riser heights are uniform....
-
11B-1009.6.1 Pool stairs
Exception: Pool step riser heights shall not be required to be 4 inches (102 mm) high minimum and 7 inches (178 mm) high maximum provided that riser heights are uniform....
-
Primary Entrances
Primary Entrances Those entrances intended to serve a majority of visitors or employees are required to be part of the minimum number made accessible to the extent "feasible."...
-
4.1.6(3)
Where substantial alteration occurs to a building or facility, then each element or space that is altered or added shall comply with the applicable provisions of 4.1.1 to 4.1.4 of 4.1, Minimum...
-
11B-1009.6.1 Pool stairs
Exception: Pool step riser heights shall not be required to be 4 inches (102 mm) high minimum and 7 inches (178 mm) high maximum provided that riser heights are uniform....
-
11B-1008.2.5.3.1 Handrail gripping surfaces
Handrail gripping surfaces with a circular cross section shall have an outside diameter of 0.95 inch (24 mm) minimum and 1.55 inches (39 mm) maximum....