Where guest rooms are altered or added, the requirements of Section 11B-224 shall apply only to the guest rooms being altered or added until the number of guest rooms complies with the minimum...
Search Results "Minimum Dimension"
-
11B-224.1.1 Alterations
-
11B-1009.2.4 Seat
The height of the lift seat shall be designed to allow a stop at 17 inches (432 mm) minimum to 19 inches (483 mm) maximum measured from the deck to the top of the seat surface when in the...
-
223.1.1 Alterations
Where sleeping rooms are altered or added, the requirements of 223 shall apply only to the sleeping rooms being altered or added until the number of sleeping rooms complies with the minimum...
-
1007.3.2 Golf Club Reach Range Area
All areas within holes where golf balls rest shall be within 36 inches (915 mm) maximum of a clear floor or ground space 36 inches (915 mm) wide minimum and 48 inches (1220 mm) long minimum...
-
Background
One-hundred and twenty adult WMD users were tested and the primary outcome measures collected were the maximum and minimum attainable vertical heights of the transfer surface, maximum gap...
-
703.2.4 Character Proportions
Characters shall be selected from fonts where the width of the uppercase letter "O" is 55 percent minimum and 110 percent maximum of the height of the uppercase letter "I"....
-
804.3 Kitchen Work Surface
In residential dwelling units required to comply with 809, at least one 30 inches (760 mm) wide minimum section of counter shall provide a kitchen work surface that complies with 804.3....
-
607.4.1.2 Control End Wall
A grab bar 24 inches (610 mm) long minimum shall be installed on the control end wall at the front edge of the bathtub. [ECTCR UFAS 4.34.5.4(3), Fig. 48(b)]...
-
11B-305.7.2 Parallel approach
Alcoves shall be 60 inches (1524 mm) wide minimum where the depth exceeds 15 inches (381 mm). FIGURE 11B-305.7.2 MANEUVERING CLEARANCE IN AN ALCOVE, PARALLEL APPROACH...
-
604.9.3 Height
The height of water closets shall be 11 inches (280 mm) minimum and 17 inches (430 mm) maximum measured to the top of the seat....
-
703.5.6 Height from Finish Floor or Ground
Visual characters shall be 40 inches (1015 mm) minimum above the finish floor or ground....
-
1009.2.8 Submerged Depth
The lift shall be designed so that the seat will submerge to a water depth of 18 inches (455 mm) minimum below the stationary water level....
-
Submerged Depth
Submerged Depth Lifts must be designed so that the seat will submerge to a minimum of 18 inches below the stationary water level....
-
703.5.6 Height From Finish Floor or Ground
Visual characters shall be 40 inches (1015 mm) minimum above the finish floor or ground....
-
1002.5.2 Transfer Height
The height of amusement ride seats designed for transfer shall be 14 inches (355 mm) minimum and 24 inches (610 mm) maximum measured from the surface of the load and unload area....
-
Doors and hardware
• Minimum-weight doors with accessible hardware are easily opened by people who have arthritis or use a cane for extra balance....
-
5.8.1.2.3 Double Ramped Entry – Edge Protection on the Platform Sides
A minimum 2 inch high edge protection must be provided on both sides of the platform for double ramped entry platforms....
-
5.2.1.2 Transfer Surface Depth
The transfer surface should be 17 inches deep minimum for all equipment used by patients in a supine, side-lying, or prone position with the exception of imaging equipment....
-
5.8.2.6 Clearance Depth at Toe Height above the ground Recommendation
5.8.2.6 Clearance Depth at Toe Height above the ground Recommendation The Committee recommends 22 inches minimum clearance depth at toe height....
-
R410.5 Character Proportions
Characters shall be selected from fonts where the width of the uppercase letter "O" is 55 percent minimum and 110 percent maximum of the height of the uppercase letter "I"....
-
§ 36.406(d)(1)
(1) In sleeping rooms with more than twenty-five beds covered by this section, a minimum of five percent (5%) of the beds shall have clear floor space complying with section 806.2.3....
-
709.3 Fire-resistance rating
Exception: Smoke barriers constructed of minimum 0.10-inch thick (2.5 mm) steel in Group I-3 buildings....
-
§ 35.151(e)(1)
(1) In sleeping rooms covered by this section with more than twenty-five beds, five percent (5%) minimum of the beds shall have clear floor space complying with section 806.2.3....
-
11B-604.9.3 Height
The height of water closets shall be 11 inches (279 mm) minimum and 17 inches (432 mm) maximum measured to the top of the seat....