Operable parts of ICT providing a forward reach shall conform to 407.12.3.1 or 407.12.3.2. The vertical reference plane shall be centered, and intersect with, the operable part....
Search Results "Reach Range"
Commonly Searched Documents
-
407.12.3 Forward Reach
-
Locating Controls & Devices: Percent of People Who Can Reach the Matrix Cell Indicated While Holding No Weight - Forward Approach Manual Wheelchair
These data depict the reaching abilities of manual chair users represented as the percentage of users expected to reach to a target location in the forward reach direction for a given...
-
Locating Controls & Devices: Percent of People Who Can Reach the Matrix Cell Indicated While Holding No Weight - Forward Approach Power Chair
These data depict the reaching abilities of power chair users represented as the percentage of users expected to reach to a target location in the forward reach direction for a given...
-
Locating Controls & Devices: Percent of People Who Can Reach the Matrix Cell Indicated While Holding No Weight - Side Approach Power Chair
These data depict the reaching abilities of power chair users represented as the percentage of users expected to reach to a target location in the lateral or sideways reach direction...
-
Locating Controls & Devices: Percent of People Who Can Reach the Matrix Cell Indicated While Holding No Weight - Side Approach Manual Wheelchair
These data depict the reaching abilities of manual chair users represented as the percentage of users expected to reach to a target location in the lateral or sideways reach direction...
-
Locating Controls & Devices: Percent of People Who Can Reach the Matrix Cell Indicated While Holding 5 lb Weight - Forward Approach Power Chair
These data depict the reaching abilities of power chair users represented as the percentage of users able to retrieve and place a 5 lb weight on a target shelf in the forward reach direction...
-
Locating Controls & Devices: Percent of People Who Can Reach the Matrix Cell Indicated While Holding 5 lb Weight - Forward Approach Manual Wheelchair
These data depict the reaching abilities of manual chair users represented as the percentage of users able to retrieve and place a 5 lb weight on a target shelf in the forward reach...
-
Locating Controls & Devices: Percent of People Who Can Reach the Matrix Cell Indicated While Holding 5 lb Weight - Side Approach Power Chair
These data depict the reaching abilities of power chair users represented as the percentage of users able to retrieve and place a 5 lb object on a target shelf in the lateral or sideways...
-
Locating Controls & Devices: Percent of People Who Can Reach the Matrix Cell Indicated While Holding 5 lb Weight - Side Approach Manual Wheelchair
These data depict the reaching abilities of manual chair users represented as the percentage of users able to retrieve and place a 5 lb object on a target shelf in the lateral or sideways...
-
Controls for Ranges and Cooktops
Other commenters objected to front range controls as a safety hazard for children. Commenters from the disability community were strongly supportive of this design specification....
-
Trailhead Information Signs [F216.13 and 1017.10]
requires operable parts in accessible spaces to comply with the technical requirements for operable parts in section 309 of the ABA Standards, including the provisions for clear ground space, reach...
-
A4.34.6.6 RANGES AND COOKTOPS
Although not required for minimum accessibility, countertop range units in a counter with adjustable heights can be an added convenience for wheelchair users....
-
4.31.3* Mounting Height
The highest operable part of the telephone shall be within the reach ranges specified in 4.2.5 or 4.2.6....
-
407.12.3 Forward Reach (Section-by-Section Analysis)
407.12.3 Forward Reach (Section-by-Section Analysis) This section contains proposed requirements for operable parts providing either an unobstructed or obstructed forward reach....
-
407.8.1.1 Vertical Plane for Side Reach
Where a side reach is provided, the vertical reference plane shall be 48 inches (1220 mm) long minimum....
-
407.8.1.2 Vertical Plane for Forward Reach
Where a forward reach is provided, the vertical reference plane shall be 30 inches (760 mm) long minimum....
-
407.12.1.1 Vertical Plane for Side Reach
Where a side reach is provided, the vertical reference plane shall be 48 inches (1220 mm) long minimum....
-
5.6 Tableware and Condiment Areas
Self-service shelves and dispensing devices for tableware, dishware, condiments, food and beverages shall be installed to comply with 4.2 (see Fig. 54).
-
Verify Electrical
VERIFY ELECTRICAL – remember finish material thicknesses! Heights of all 30 amp or less outlet boxes. Measure to top or bottom of...
-
Verify Electrical
VERIFY ELECTRICAL – remember finish material thicknesses! Heights of all 30 amp or less outlet boxes. Measure to top or bottom of...
-
5.3 TABLEWARE AREAS
Install tableware, dishware, condiment, food and beverage display shelves, and dispensing devices in compliance with 4.2 (see Fig. 54).
-
§ 38.107(a)(4)
(4) Faucets and flush controls shall be operable with one hand and shall not require tight grasping, pinching, or twisting of the wrist. The force required to activate controls shall...
-
407.12.1.2 Vertical Plane for Forward Reach
Where a forward reach is provided, the vertical reference plane shall be 30 inches (760 mm) long minimum. Figure 407.12.1...