vehicular or pedestrian arrival points within 50 feet of the planned entrance, the unusual characteristics result in a difference in finished grade elevation exceeding 30 inches and 10 percent measured...
Search Results "Unit of Measurement"
-
1(2)(b)(ii)
-
1134A.6, Item 1.3
1.3 Other shower stall configurations shall measure at least 36 inches deep by 60 inches wide (914 mm by 1524 mm) with an entrance opening of at least 36 inches (914 mm) when a wall is...
-
§35.130(f)
(f) A public entity may not place a surcharge on a particular individual with a disability or any group of individuals with disabilities to cover the costs of measures, such as the provision...
-
Grade
Grade—The difference in elevation of a section of an outdoor recreation access route, trail, or beach access route measured parallel to the predominant direction of travel....
-
4.13.10* Door Closers
then the sweep period of the closer shall be adjusted so that from an open position of 70 degrees, the door will take at least 3 seconds to move to a point 3 in (75 mm) from the latch, measured...
-
R305.1.2 Dome Spacing
The truncated domes shall have a center-to-center spacing of 41 mm (1.6 in) minimum and 61 mm (2.4 in) maximum, and a base-to-base spacing of 17 mm (0.65 in) minimum, measured between the...
-
4.13.10* DOOR CLOSERS
then the sweep period of the closer shall be adjusted so that from an open position of 70 degrees, the door will take at least 3 seconds to move to a point 3 in (75 mm) from the latch, measured...
-
Cross Slope
The difference in elevation from edge to edge of an ORAR, trail, or beach access route measured perpendicular to the direction of travel. ...
-
Detail View – Accessible Round Set-Up
Measure from the back of one chair to the back of the chair directly behind it. Chairs must be set with the front edge of the chair at the edge of the table....
-
Running Slope (Grade)
The difference in elevation of a section of an ORAR, trail, or beach access route measured parallel to the predominant direction of travel. ...
-
2.4.1
2.4.1 Based on the methods for measuring compliance, define what remedial actions are acceptable when construction elements exceed tolerances....
-
Laser scanners
These types of instruments could be used to measure floor flatness and level but they are very expensive, require training, and give accuracies in excess of what is needed for accessible...
-
1134A.6, Item 1.3
Other shower stall configurations shall measure at least 36 inches deep by 60 inches wide (914 mm by 1524 mm) with an entrance opening of at least 36 inches (914 mm) when a wall is installed...
-
§ 35.130(f)
(f) A public entity may not place a surcharge on a particular individual with a disability or any group of individuals with disabilities to cover the costs of measures, such as the provision...
-
11B-703.5.8 Character spacing
Character spacing shall be measured between the two closest points of adjacent characters, excluding word spaces....
-
1002.4.4.1 Width and Length
Wheelchair spaces shall provide a clear width of 30 inches (760 mm) minimum and a clear length of 48 inches (1220 mm) minimum measured to 9 inches (230 mm) minimum above the floor surface...
-
BATHROOM
A compartmented bathroom is considered a single unit and is subject to the requirements of Chapters 11A and 11B....
-
BATHROOM
A compartmented bathroom is considered a single unit and is subject to the requirements of Chapters 11A and 11B....
-
2.2
2.2 This Consent Order shall be a full, complete, and final disposition and settlement of all of the United States' and Cinemark's claims between the parties that have arisen in this...
-
§27.125(a)(1)
(1) A referral to the Department of Justice with a recommendation that appropriate proceedings be brought to enforce any rights of the United States under any law of the United States (including...
-
1(3)(a)(i)
(i) Where a building elevator is provided only as a means of creating an accessible route to dwelling units on a ground floor, the building is not considered an elevator building for purposes...
-
1(3)(a)
(a) There is an elevator connecting the parking area with the dwelling units on a ground floor....
-
§100.305(e)(5)(i)
(i) Has reserved all unoccupied units for occupancy by at least one person 55 years of age or older until at least 80 percent of the units are occupied by at least one person who is 55 years...
-
Wheelbase Definition
Wheelbase Definition For the purpose of this analysis, wheelbase is defined as the distance from the center of the primary drive wheel to the center of the caster measured parallel to...