1.1.10 Ramps. Measure accessible ramps for overall running slope and cross slope as well as local running slope and cross slope variations (flatness) in accordance with Sections...
Search Results "Fire-Building Surface"
Commonly Searched Documents
-
1.1.10 Ramps
-
1.1.14 Flatness of ramp cross slope
1.1.14 Flatness of ramp cross slope. For ramps, measure flatness of cross slope by placing a 24 - in. (600 mm) digital inclinometer perpendicular to the line of travel at 4 ft (1200...
-
11B-810.2.4 Slope
Parallel to the roadway, the slope of the bus stop boarding and alighting area shall be the same as the roadway, to the maximum extent practicable. Perpendicular to the roadway, the...
-
11B-810.2.4 Slope
Parallel to the roadway, the slope of the bus stop boarding and alighting area shall be the same as the roadway, to the maximum extent practicable. Perpendicular to the roadway, the...
-
11B-1002.2 Accessible routes
In load or unload areas and on amusement rides, handrails provided along walking surfaces complying with Section 11B-403 and required on ramps complying with Section 11B-405 shall not be...
-
11B-1002.2 Accessible routes
In load or unload areas and on amusement rides, handrails provided along walking surfaces complying with Section 11B-403 and required on ramps complying with Section 11B-405 shall not be...
-
11B-1002.2 Accessible routes
. ◼ In load or unload areas and on amusement rides, handrails provided along walking surfaces complying with Section 11B-403 and required on ramps complying with Section 11B...
-
Is clear floor space required to be centered on elements?
The standards require the clear floor space to be centered on wheelchair accessible drinking fountains (forward approach), kitchen work surfaces, (forward approach), and washers and dryers...
-
Height – M301.2.1 & M302.2.1
Height – M301.2.1 & M302.2.1 The subcommittee discussed the increments for adjustability and decided that infinite adjustability is the appropriate standard as both electronic...
-
5.3.2.2 Transfer Sides Recommendation for Imaging Equipment
5.3.2.2 Transfer Sides Recommendation for Imaging Equipment On imaging equipment, the transfer surface is oriented along the long dimension of the surface on which patients are in the...
-
DSA IR 11B-8 - USE OF PREDETERMINED CONSTRUCTION TOLERANCE GUIDELINES FOR ACCESSIBILITY (with revisions issued through Jan. 2011)
Interpretation of Regulations Document IR 11B-8 USE OF PREDETERMINED CONSTRUCTION TOLERANCE GUIDELINES FOR ACCESSIBILITY References: 2007/2010 California Building Code, Section...
-
5.4.7 Transfer Support Gripping Surface Clearance for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
5.4.7 Transfer Support Gripping Surface Clearance for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position....
-
M305.3.1 Length
The length of gripping surfaces for standing supports shall be based on the position of the standing supports in relation to the standing surfaces they serve....
-
711.3 Fire-resistance-rated walls
Penetrations into or through fire walls, fire barriers, smoke barrier walls, and fire partitions shall comply with this section....
-
Single riser stair handrail extension
A stair is defined as one or more risers. For a stair with one riser only, what is the length of the bottom handrail exension required?
-
7(1)(a)
(a) A clear floor space at least 30 inches by 48 inches that allows a parallel approach by a person in a wheelchair is provided at the range or cooktop and sink, and either a...
-
VI. Relationship to Other Laws
‘‘Covered multifamily dwellings’’ means all buildings consisting of four or more dwelling units: In buildings without an elevator, all of the ground floor dwelling units are covered; in...
-
6. Fire Safety
Are fire-safety information, maximum room rate information, telephone and television information cards, guest services guides, restaurant menus, room service menus, and all other printed...
- Accessible Parking Video Fact Sheet
-
5.3.2.2 Transfer Sides for Imaging Equipment
The transfer surface should be provided on at least one long side of the table....
-
Reach Ranges
Changes in the side-reach range for new construction and alterations in the 2010 Standards will affect a variety of building elements such as light switches, electrical outlets, thermostats...
-
Section B: Passenger Drop-Off Area
Yes No N/A Comments/Remedies B1 Is the vehicle pull-up space on a level surface, with slopes not exceeding 1:48 in all directions?...
-
5.4.5.1 Transfer and Positioning Support Position Recommendation for Imaging Equipment
5.4.5.1 Transfer and Positioning Support Position Recommendation for Imaging Equipment On imaging equipment, the transfer surface is oriented along the long dimension of the surface where...