interior and exterior accessible routes, including walking surfaces, ramps, elevators, and lifts stairways that are part of a means of egress required clearances, including clear...
Search Results "Clear Width at Turn"
Commonly Searched Documents
-
Floor and Ground Surfaces
-
FIGURE INDEX
Pile Height Figure 302.3 Elongated Openings in Floor or Ground Surfaces Figure 303.2 Vertical Change in Level Figure 303.3 Beveled Change in Level Figure 304.3.2 T-Shaped Turning...
-
11B-704.2.1.2 Forward approach
Where a forward approach is provided at a telephone within an enclosure, the counter may extend beyond the face of the telephone 20 inches (508 mm) into the required clear floor or ground...
-
Length: ADA Standard Section 503.3.2
Section 503.3.2 covers the current ADA Standards for the required length of access aisles at passenger loading zones.
-
Entrances: ADA Standard Section 206.5.1
Section 206.5.1 covers scoping requirements in the most current ADA Standards for doors, doorways, and gates at entrances.
-
Toilet Rooms and Bathing Rooms: ADA Standard Section 216.8
Section 216.8 covers scoping requirements in the current ADA Standards for signs at toilet rooms and bathing rooms.
-
Team or Player Seating: ADA Standard Section 221.2.1.4
Section 221.2.1.4 covers scoping requirements in the current ADA Standards for wheelchair spaces at team or player seating.
-
Maneuvering Clearance: ADA Standard Section 404.3.2
Section 404.3.2 covers the current ADA Standards for maneuvering clearance at automatic and power-assisted doors and gates.
-
11B-1003.3 Clearances
Although the minimum width of the clear pier space is 60 inches (1525 mm), it is recommended that piers be wider than 60 inches (1525 mm) to improve the safety for persons with disabilities...
-
11B-1003.3 Clearances
Although the minimum width of the clear pier space is 60 inches (1525 mm), it is recommended that piers be wider than 60 inches (1525 mm) to improve the safety for persons with disabilities...
-
11B-1003.3 Clearances
Although the minimum width of the clear pier space is 60 inches (1525 mm), it is recommended that piers be wider than 60 inches (1525 mm) to improve the safety for persons with disabilities...
-
Lavatory & Accessory Layouts
The trash receptacle is preferred to be near the door to allow people to pull the door open with a paper towel and drop it into the receptacle before exiting.
- GE® 27" Drop-In Electric Range JM250DFBB
-
11B-608.2.2 Standard roll-in type shower compartments
Standard roll-in type shower compartments shall be 30 inches (762 mm) wide minimum by 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides...
-
10.2.1(1)
(1) Where new bus stop pads are constructed at bus stops, bays or other areas where a lift or ramp is to be deployed, they shall have a firm, stable surface; a minimum clear length of 96...
-
11B-608.2.2 Standard roll-in type shower compartments
Standard roll-in type shower compartments shall be 30 inches (762 mm) wide minimum by 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides...
-
11B-704.2.1.2 Forward approach
Where a forward approach is provided at a telephone within an enclosure, the counter may extend beyond the face of the telephone 20 inches (508 mm) into the required clear floor or ground...
-
11B-704.2.1.2 Forward approach
Where a forward approach is provided at a telephone within an enclosure, the counter may extend beyond the face of the telephone 20 inches (508 mm) into the required clear floor or ground...
-
Serving Counters
A minimum width of 36 inches should be provided with a 42 inch width preferred, if readily achievable....
-
Mechanical Access Parking Garages: ADA Standard Section 209.5
Section 209.5 covers scoping requirements in the current ADA Standards for passenger loading zones at mechanical access parking garages.
-
Overlap: ADA Standard Section 802.1.5
The term “circulation paths” used in Section 802.1.5 means aisle width required by applicable building or life safety codes for the specific assembly occupancy....
-
2. Shoulder Breadth
Inadequate seat width can be more problematic for individuals that have broader shoulders and/or are obese....
-
Passing Spaces (R302.4) (Section-by-Section Analysis)
Passing Spaces (R302.4) (Section-by-Section Analysis) Where the clear width of pedestrian access routes is less than 1.5 meters (5 feet), passing spaces must be provided at intervals...
-
11B-802.1.5 Overlap
The term "circulation paths" used in Section 11B-802.1.5 means aisle width required by applicable building or life safety codes for the specific assembly occupancy....