5.4.4 Transfer Support Distance from Transfer Surface Recommendations for M301 and M302 Description: This minimum distance ensures that the transfer support is within reach of the...
Search Results "Infusion Chair"
Commonly Searched Documents
-
5.4.4 Transfer Support Distance from Transfer Surface Recommendations for M301 and M302
-
5.4 Transfer Supports
5.4 Transfer Supports.
-
5.4 Transfer Supports Recommendations
5.4 Transfer Supports Recommendations
-
M305.2 Transfer Supports
Transfer supports shall comply with M305.2.
-
Emergency Evacuation Preparedness: Take Responsibility for Your Safety
The media repeatedly reported stories about the two wheelchair users who successfully escaped from the World Trade Center using evacuation chairs on September 11th, 2001....
-
M305.2.2.1 End Transfer Supports
Transfer supports for transfer surfaces complying with M301.2.3.1 and M305.2.2.1 shall be 15 inches (380 mm) long minimum. Transfer supports shall be positioned along 13 ½ inches...
-
M305.2.4.1 Circular Cross Section
Transfer supports with circular cross sections shall have an outside diameter of 1 ¼ inches (32 mm) minimum and 2 inches (51 mm) maximum.
-
M305.2.1.2 Side Transfer Supports
Transfer supports for transfer surfaces complying with M301.2.3.2 shall be capable of supporting transfer on each side of the transfer surface.
-
M305.2.1.1 End Transfer Supports
Transfer supports for transfer surfaces complying with M301.2.3.1 and M302.2 shall be located on the short side (length) opposite the transfer side.
-
M305.2.2.2 Side Transfer Supports
Transfer supports for transfer surfaces complying with M301.2.3.2 shall be 28 inches (710 mm) long minimum and shall be positioned along the width of transfer...
-
M305.2.1 Location (Section-by-Section Analysis)
The MDE NPRM proposed that transfer supports be located within reach of the transfer surface and not obstruct transfer onto or off of the surface when in position (proposed...
-
5.3.1 Permitted Obstructions to Transfer Sides for Equipment Used by Patients in a Supine, Prone, Side-Lying or Seated Position
5.3.1 Permitted Obstructions to Transfer Sides for Equipment Used by Patients in a Supine, Prone, Side-Lying or Seated Position. A 3-inch maximum obstruction is permitted at transfer...
-
5.4.3 Transfer Support Height for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
5.4.3 Transfer Support Height for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position. Transfer supports should be positioned 6 inches minimum and 19 inches maximum...
-
5.4.3 Transfer Support Height for M301 and M302
5.4.3 Transfer Support Height for M301 and M302 Description: Transfer support height applies to the vertical distance that the gripping area of the support is above the transfer...
- The UpScale Medical Exam Table
- Stable and rock solid. See for yourself!
- Exam Tables & Scales: What Patients Say...
-
M305.2.4.2 Non-Circular Cross Section
Transfer supports with non-circular cross sections shall have a cross-section dimension of 2 inches (51 mm) maximum and a perimeter dimension of 4 inches (100 mm) minimum and 4.8...
-
5.4.8 Transfer Support Gripping Surface Hazard Recommendation for M301 and M302
5.4.8 Transfer Support Gripping Surface Hazard Recommendation for M301 and M302 Description: Gripping surface hazards are sharp or abrasive elements that prevent an individual...
-
5.4.8 Transfer Support Gripping Surface Hazard for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
5.4.8 Transfer Support Gripping Surface Hazard for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position. The gripping surfaces of the transfer support must be free of...
-
Introduction
[See subsections ...]
-
Accessible Medical Equipment
For participants with mobility limitations, we use exam and procedural tables and chairs that: [See Resources below and Section H] D.1....
- Big John Commode Chair BJBC
- Mobi-Chair® by Deschamps Floating Beach Wheelchair