elevators, does it have areas of refuge (fire-rated spaces where people who cannot use stairs can go to register a call for help and wait for responders), or Are there evacuation chairs...
Search Results "Infusion Chair"
Commonly Searched Documents
-
Emergency Planning
-
M102.1 Defined Terms (Section-by-Section Analysis)
supports, positioning supports, prone position, supine position, examination tables, diagnostic purposes, maximum extent possible, landing area, exam table, procedure table, and procedure chair...
-
M302 Diagnostic Equipment Used by Patients in Seated Position
[See subsections ...]
-
M302 Diagnostic Equipment Used by Patients in Seated Position
[See subsections ...]
-
A. Medical equipment and furniture
Medical equipment and furniture Without accessible medical examination tables, dental chairs, radiological diagnostic equipment, scales, and rehabilitation equipment, individuals with...
-
§ 382.38 Seating accommodations
disability specified in this paragraph, the carrier shall provide the following seating accommodations, subject to the provisions of this section: (1) For a passenger who uses an aisle chair...
- How to: wrap your levers
-
§382.81 For which passengers must carriers make seating accommodations?
As a carrier, you must provide the following seating accommodations to the following passengers on request, if the passenger self-identifies to you as having a disability specified...
-
382.81 For which passengers must carriers make seating accommodations?
382.81 For which passengers must carriers make seating accommodations? ETA Editor's Note This section has no content in the original document.
-
M302.4.1 Clearance in Base
The base of the diagnostic equipment shall provide a clearance 39 inches (990 mm) wide minimum, 6 inches (150 mm) high minimum measured from the floor, and 36 inches (915 mm) deep...
-
M302.4.1 Clearance in Base
The base of the equipment shall provide a clearance 44 inches (1120 mm) wide minimum, 6 inches (150 mm) high minimum measured from the floor, and 36 inches (915 mm) deep minimum...
-
M301.1 General (Section-by-Section Analysis)
(Significant Changes – Exception from the Requirements of M301 for Certain Examination Chairs that Comply with M302), in response to public comment and recommendations from the MDE Advisory...
-
M302.4.2 Clearance Around Base
The base of the diagnostic equipment shall provide a clearance 6 inches (150 mm) high minimum measured from the floor and 36 inches (915 mm) deep minimum measured from the edge of...
-
M302.4.2 Clearance Around Base
The base of the equipment shall provide a clearance 6 inches (150 mm) high minimum measured from the floor and 36 inches (915 mm) deep minimum measured from the edge of the...
-
11B-805 Medical care and long-term care facilities
SECTIONS 11B-805 Medical care and long-term care facilities 11B-805.4.1 Beds, exam tables, procedure tables, gurneys and lounge chairs....
-
Features of an Accessible Examination Room
Note: Additional clear floor space can be provided by moving or relocating chairs, trash cans, carts, and other items....
-
Evaluate Your Need to Identify as Someone Who Requires Assistance During an Evacuation
(Bondi 2001) (Juillet 1993) Two men who helped a wheelchair user transfer to an evacuation chair hanging in the stairwell of the World Trade Center on September 11, 2001, and transported...
-
Examples of access:
A patient with poor balance can walk onto the scale or get weighed sitting in a chair....
- Amos Winter: The cheap all-terrain wheelchair | TED Talks
-
Checklist for Inclusive Emergency Safety Briefings for Attendees
accessible exit pathways emergency meeting areas outside the facility evacuation devices are fold‑up chairs...
- Brewer Access™ High-Low Exam Table
-
PART 3: ACCESSIBLE EXAMINATION ROOMS
An accessible examination room has features that make it possible for patients with mobility disabilities, including those who use wheelchairs, to receive appropriate medical care....
-
M302.4 Lift Compatibility
Diagnostic equipment shall be usable with portable patient lifts and, when in use with such lifts, shall comply with M302.4.1 or M302.4.2. EXCEPTION: Where fixed overhead patient...
-
M302.4 Lift Compatibility (Section-by-Section Analysis)
The MDE NPRM proposed to require that diagnostic equipment used by patients in the seated position be usable with a patient lift and comply with either the proposed clearance in base...