Section 604.5.2, Exception 1 permits a shorter grab bar on the rear wall where there is not enough wall space due to special circumstances (e.g., when a lavatory or other recessed fixture...
Search Results "Control End Wall"
-
Water Closet Location and Rear Grab Bar
-
608.3.3 Alternate Roll-In Type Shower Compartments
In alternate roll-in type shower compartments, grab bars shall be provided on the back wall and the side wall farthest from the compartment entry....
-
11B-608.3.3 Alternate roll-in type shower compartments
In alternate roll-in type shower compartments, grab bars shall be provided on the back wall and the side wall farthest from the compartment entry....
-
A. Measuring Slope and Cross Slope
While holding the uphill end of the level on the pavement, place the pencil under the other end and roll it toward the uphill end of the level until the horizontal air bubble in the center...
- Bobrick Koala Kare Horizontal, Stainless Steel Wall Mounted Baby Changing Station KB110-SSWM
-
409.3.2 Location
Elevator car doors or gates shall be positioned at the narrow end of the clear floor spaces required by 409.4.1....
-
409.3.2 Location
Elevator car doors or gates shall be positioned at the narrow end of the clear floor spaces required by 409.4.1....
-
11B-608.3.3 Alternate roll-in type shower compartments
In alternate roll-in type shower compartments, grab bars shall be provided on the back wall and the side wall farthest from the compartment entry....
-
11B-604.2 Location
The water closet shall be positioned with a wall or partition to the rear and to one side....
-
11B-604.2 Location
The water closet shall be positioned with a wall or partition to the rear and to one side....
-
11B-604.5 Grab bars
Grab bars shall be provided on the side wall closest to the water closet and on the rear wall....
-
11B-604.5 Grab bars
Grab bars shall be provided on the side wall closest to the water closet and on the rear wall....
- EZConcept – Global Architectural Solutions
-
382.51 What requirements must carriers meet concerning the accessibility of airport facilities?
Inter-terminal and intra-terminal transportation owned, leased, or controlled by a carrier at a U.S. airport must meet DOT ADA rules....
-
2. Typical Issues for People Who are Blind or Have Low Vision
Items to watch for include wall-mounted fire extinguishers and wall-mounted display cases when the bottom is more than 27 inches above the floor, wall sconces and light fixtures that protrude...
-
1011.5 Fire Rings, Grills, Fireplaces, and Wood Stoves
Where fire rings, grills, or fireplaces are constructed with raised edges or walls, the depth of the raised edge or wall is required to be 10 inches maximum....
-
604.5 Grab Bars
Grab bars shall be provided on the side wall closest to the water closet and on the rear wall. Advisory 604.5 Grab Bars Exception 2....
-
607.3 Seat
A permanent seat at the head end of the bathtub or a removable in-tub seat shall be provided. Seats shall comply with 610....
-
607.3 Seat
A permanent seat at the head end of the bathtub or a removable in-tub seat shall be provided. Seats shall comply with 610....
-
12162(a)(4)(A)(i)(I)
(I) the car adjacent to the end of the dining car through which a wheelchair may enter is itself accessible to a wheelchair;...
-
§1193.33(a)(2)
(2) Providing end-user product documentation in alternate formats or alternate modes upon request at no additional charge; and...
-
1134A.6, Item 4
Reinforced walls for grab bars. Grab bar reinforcement shall be installed continuous in the walls of showers 32 inches to 38 inches (813 mm to 965 mm) above the floor....
-
608.3.3 Alternate Roll-In Type Shower Compartments
In alternate roll-in type shower compartments, grab bars shall be provided on the back wall and the side wall farthest from the compartment entry....
-
1134A.6, Item 4
Reinforced walls for grab bars. Grab bar reinforcement shall be installed continuous in the walls of showers 32 inches to 38 inches (813 mm to 965 mm) above the floor....