Floors of amusement rides with wheelchair spaces and floors of load and unload areas shall be coordinated so that, when amusement rides are at rest in the load and unload position, the vertical...
Search Results "Vertical Clearance"
Commonly Searched Documents
-
1002.4.3 Gaps
-
Water closet
With grab bars in the vertical or up position, sufficient space was provided for caregivers to stand next to the toilet on either (or both) side(s) to provide support getting on and off...
-
Slope [§405.2] and Cross Slope [§405.3]
Slope [§405.2] and Cross Slope [§405.3] Slope represents the proportion of vertical rise to horizontal length and is specified in the Standards as a ratio (e.g., 1:12)....
-
Changes in Level at Entry to Wheelchair Spaces (M303.3)
Level changes up to ¼ inch high are permitted to be vertical. Level changes between ¼ inch high and ½ inch high would be required to be beveled with a slope not steeper than 1:2....
-
11B-1002.4.3 Gaps
Floors of amusement rides with wheelchair spaces and floors of load and unload areas shall be coordinated so that, when amusement rides are at rest in the load and unload position, the vertical...
-
18) Elevators and platform lifts in new construction and alterations
Therefore, elevators are required in all new multilevel buildings or facilities, but vertical access to elevator pits, elevator penthouses, mechanical rooms, and piping or equipment catwalks...
-
11B-1002.4.3 Gaps
Floors of amusement rides with wheelchair spaces and floors of load and unload areas shall be coordinated so that, when amusement rides are at rest in the load and unload position, the vertical...
-
11B-703.7.2.6 Toilet and bathing facilities geometric symbols
Where a door is provided the symbol shall be mounted within 1 inch (25 mm) of the vertical centerline of the door....
-
Edge Protection
Toe clearance must be at least 30 inches wide and a minimum of 9 inches above the ground or deck surface beyond the railing....
-
226.1 General
However, employers should consider work surfaces that are flexible and permit installation at variable heights and clearances....
-
4) Medical or health care facilities
Required clearances in rooms exceed ADAAG requirements. No special, less stringent requirements for alterations (§6)....
- Just Manufacturing Classroom Concealed Ledgemount Teardrop Handles Restricted Swing Faucet
- Just Manufacturing Concealed Classroom Faucet with High Rise Spout
- CRL Jackson 900 Series Floor Mounted Door Closers
- Kawneer North America 350/500 Heavy Wall™ Entrances
- Kessel Design Linearis Super60 Trench Drain
-
Chapter 1: Background
The primary goal of this project is to determine acceptable ranges for non-level transfers (e.g. vertical height differences), gaps between the transfer surface and wheelchair, and the clear...
-
11B-604.5.1 Side wall
(CEC) requires a nurse call device at the side wall of a water closet that must be coordinated carefully with the side grab bar at an accessible water closet to ensure that accessible clearances...
-
212 and 606 Kitchens, Kitchenettes, Lavatories, and Sinks
The 1991 Standards, at section 4.24, and the 2010 Standards, at section 606, both require the clear floor space at sinks to be positioned for a forward approach and knee and toe clearance...
- LifeGuard Pool Lift #100287
- Bobrick Swing-Up Grab Bar B-4998
- SafePath Courtedge™ Reducer Ramps
-
1002.4.4.2 Side Entry
Where wheelchair spaces are entered only from the side, amusement rides shall be designed to permit sufficient maneuvering clearance for individuals using a wheelchair or mobility aid to...
-
Doorways