If the high forward reach is over an obstruction, reach and clearances shall be as shown in Fig. 5(b). Figure 5 Forward Reach...
Search Results "Vertical Clearance"
-
4.2.5 FORWARD REACH
-
4.18.3 CLEAR FLOOR SPACE
Urinal shields that do not extend beyond the front edge of the urinal rim may be provided with 29 in (735 mm) clearance between them....
-
§ 38.159(a)(1) General
., lift or ramp) complying with paragraph (b) or (c) of this section and sufficient clearances to permit a wheelchair or other mobility aid user to reach a securement location....
-
a. Structural Strength
The MDE NPRM proposed to require transfer supports to be capable of resisting vertical and horizontal forces of 250 pounds at all points (proposed M305.2.2)....
-
4.3.9 Doorway Design
The lack of differences between the findings for the passage task on the pull sides of Doors 1, 800 mm (31.5 in.) latch clearance, and Door 2, 406 mm (16 in.) latch clearance, demonstrate...
-
4.10.9 Floor Plan of Elevator Cars
The clearance between the car platform sill and the edge of any hoistway landing shall be no greater than 1‒1/4 in (32 mm)....
-
4.10.9 FLOOR PLAN OF ELEVATOR CARS
The clearance between the car platform sill and the edge of any hoistway landing shall be no greater than 1-1/4 in (32 mm)....
-
Clear Floor or Ground Space and Turning Space
Clearances are required at accessible elements, fixtures, and controls so that people with disabilities, including those who use wheelchairs, can approach and use them....
-
304 Turning Space
Objects that provide sufficient knee and toe clearance can overlap a limited portion of the turning space. Comment....
-
Section 810.2.2
We note that there may be some instances in which it will be necessary to make operational adjustments where sufficient clearance is not available to permit the deployment of lifts or ramps...
- Bobrick TrimLineSeries ADA Surface-Mounted Hand Dryer B-7128.115V
-
Feature 2 - Routes to the Building Entrance
Ramps with a vertical rise of more than 6 inches must have handrails on both sides....
-
303.3 Beveled
A change in level of ½ inch (13 mm) is permitted to be ¼ inch (6.4 mm) vertical plus ¼ inch (6.4 mm) beveled....
-
206.3 Location
Additionally, accessible vertical interior circulation must be in the same area as stairs and escalators, not isolated in the back of the facility....
-
11B-404.3.5 Controls
Where push plates, vertical actuation bars or other similar operating devices are provided, they shall be placed in a conspicuous location. ...
-
11B-602.9 Pedestrian protection
When used, wing walls or barriers shall project horizontally at least as far as the drinking fountain and to within 6 inches (152 mm) vertically from the floor or ground surface....
-
§ 38.83(b)(7) Platform gaps
floor height with the inner barrier (if applicable) down or retracted, gaps between the forward lift platform edge and vehicle floor shall not exceed 1/2 inch horizontally and 5/8 inch vertically...
-
11B-404.3.5 Controls
Where push plates, vertical actuation bars or other similar operating devices are provided, they shall be placed in a conspicuous location....
-
§ 38.23(b)(7) Platform gaps
floor height with the inner barrier (if applicable) down or retracted, gaps between the forward lift platform edge and the vehicle floor shall not exceed 1/2 inch horizontally and 5/8 inch vertically...
-
11B-303.5 Warning curbs
Abrupt changes in level exceeding 4 inches (102 mm) in a vertical dimension between walks, sidewalks or other pedestrian ways and adjacent surfaces or features shall be identified by warning...
-
11B-602.9 Pedestrian protection
When used, wing walls or barriers shall project horizontally at least as far as the drinking fountain and to within 6 inches (152 mm) vertically from the floor or ground surface....
-
11B-404.3.5 Controls
Where push plates, vertical actuation bars or other similar operating devices are provided, they shall be placed in a conspicuous location....
-
Re: 404.2.6 Doors in Series and Gates in Series
To summarize my opinion, you need compliant door maneuvering clearance at each door, AND space to avoid fighting two doors at once....
- SDC S6000 Spectra Exit Devices