for easy installation Primer-less silicone sealant available in 28.7oz [849 ml] cartridges or 2.63 US gallon [108 L] pails - Self leveling (horizontal applications) - Gun grade (vertical...
Search Results "Vertical Clearance"
Commonly Searched Documents
- Inpro Corporation JointMaster® 925 Fire Barrier System Expansion Joint Systems
- Grohe Grandera Two-Handle Bidet Mixer 1/2" M-Size Faucet
-
2.2.3 Functional Reach
The five heights were normalized to the individual's vertical reach capabilities so that reaches were performed at, above and below shoulder height....
-
QUESTION: WHEN A RAIL OPERATOR CONSTRUCTS A NEW STATION PLATFORM OR ALTERS AN EXISTING STATION PLATFORM, DOES 49 CFR PART 37 REQUIRE THE RAIL OPERATOR ENSURE THAT THE PLATFORM IS AT LEAST 8 INCHES ABOVE TOP OF RAIL, EVEN IF THE RAILROAD OPERATOR WILL PROVIDE ACCESSIBILITY CONSISTENT WITH THE REQUIREMENTS OF SECTION 37.42?
., elderly persons) who might have difficulty ascending a vertical distance greater than the normal vertical gap between an 8-inch ATR platform and the first step of a railroad car....
-
233.1 General
Florida vertical accessibility requirements of s.553.509, F.S., as incorporated in section 201.1.1 require vertical access to all levels for accessible units....
-
608.6 Shower Spray Unit and Water
If an adjustable-height shower head on a vertical bar is used, the bar shall be installed so as not to obstruct the use of grab bars....
-
Shower Threshold
However, the Board has revised the specification to allow thresholds at transfer compartments to be vertical or rounded instead of beveled....
-
608.6 Shower Spray Unit and Water
If an adjustable-height shower head on a vertical bar is used, the bar shall be installed so as not to obstruct the use of grab bars....
-
4. COMMON PATH OF TRAVEL ITEMS
Running slope of ramps, not to exceed 1:12 (8.33%) • Cross slope of walks and ramps not to exceed 1:48 (2.083%) • Landings and level area slopes not to exceed 1:48 (2.083%) • Vertical...
-
5.4.9 Interruptions along Transfer Support Gripping Recommendation for M301 and M302
Section 505.6 specifies that the gripping surface on the vertical support structure that is necessary for supporting the grip must not be discontinuous....
-
11B-504.5 Nosings
Risers shall be permitted to slope under the tread at an angle of 30 degrees maximum from vertical....
-
4.34.3(2)(b) Reach Depth More Than 10 in
Where the reach depth to the operable parts of any control as measured from the vertical plane perpendicular to the edge of the unobstructed clear floor space at the farthest protrusion...
-
Character Height [4.30.3]
Recommendations: Both the horizontal and vertical viewing distance should be considered....
-
Location
Van-accessible parking spaces located in parking garages may be clustered on one floor (to accommodate the 98-inch minimum vertical height requirement)....
-
Location
Van-accessible parking spaces located in parking garages may be clustered on one floor (to accommodate the 98-inch minimum vertical height requirement)....
-
11B-504.5 Nosings
Risers shall be permitted to slope under the tread at an angle of 30 degrees maximum from vertical....
-
11B-504.5 Nosings
Risers shall be permitted to slope under the tread at an angle of 30 degrees maximum from vertical....
-
11B-604.5.1 Side wall
2013 CEC) requires a nurse call device at the side wall of a water closet that must be coordinated carefully with the side grab bar at an accessible water closet to ensure that accessible clearances...
- Landscape Forms Inc. Towne Square Bench Collection
- PEMKO 5" Latching Panic Saddle Threshold No. 2006-P
- PEMKO 4" Latching Panic Saddle Threshold No. 278x224-FGT
- PEMKO 5" Latching Panic Saddle Threshold No. 2006-V
- Symmetry Limited Use/Limited Application (LU/LA) Elevator
- Populas Accella Adjustable Activity / Computer Workstation