Parallel to the roadway, the slope of the bus stop boarding and alighting area shall be the same as the roadway, to the maximum extent practicable....
Search Results "Clear Floor Area"
Commonly Searched Documents
-
11B-810.2.4 Slope
-
11B-810.2.4 Slope
Parallel to the roadway, the slope of the bus stop boarding and alighting area shall be the same as the roadway, to the maximum extent practicable....
-
4.4.1* General
Objects projecting from walls (for example, telephones) with their leading edges between 27 in and 80 in (685 mm and 2030 mm) above the finished floor shall protrude no more than 4 in (100...
-
§27.75(b) Existing facilities—Rest area facilities.
(b) Existing facilities—Rest area facilities....
-
221.2.1.1 General Seating
Number of Wheelchair Spaces in Assembly Areas Number of Seats Minimum Number of Required Wheelchair Spaces 4 to 25...
-
810.2.4 Slope
Parallel to the roadway, the slope of the bus stop boarding and alighting area shall be the same as the roadway, to the maximum extent practicable....
-
Common Use Circulation Paths in Employee Work Areas Over 1,000 SF
[See subsections ...]
-
1011.2.4 Openings
Openings in the clear ground space surface shall not allow the passage of a sphere more than 1/2 inch (13 mm) in diameter. Advisory 1011.2.4 Openings. ...
-
1011.2.4 Openings
Openings in the clear ground space surface shall not allow the passage of a sphere more than 1/2 inch (13 mm) in diameter. Advisory 1011.2.4 Openings....
-
Car Controls [4.10.12]
Control panels must be located so that no floor button is higher than 54 inches for a side reach and 48 inches for a front approach....
-
11B-302.3 Openings
Openings in floor or ground surfaces shall not allow passage of a sphere more than ½ inch (12.7 mm) diameter except as allowed in Sections 11B-407.4.3 _|Platform to Hoistway Clearance|_,...
-
Openings [§302.3]
Openings [§302.3] Openings in ground and floor surfaces, such as grates, are limited in width to prevent passage of a ½” diameter sphere....
-
221.2.1.1 General Seating
Table 221.2.1.1 Number of Wheelchair Spaces in Assembly Areas Number of Seats Minimum Number of Required Wheelchair Spaces 4...
-
7(1)(b)
(b) Clearance between counters and all opposing base cabinets, countertops, appliances or walls is at least 40 inches.
-
4.34.5.2 WATER CLOSETS
[See subsections ...]
-
K5
If the operating controls are set back 10 to 24 inches from the front edge of the counter or table are they no higher than 46 inches above the floor?...
-
§ 38.153(c)(1)
(1) Doors shall have a minimum clear width when open of 30 inches (760 mm), measured from the lowest step to a height of at least 48 inches (1220 mm), from which point they may taper to...
- Figure 1009.2.2 Pool Lift Seat Location – Drawing from the U.S. Access Board
- Figure 1009.3.3 Handrails for Sloped Entry – Drawing from the U.S. Access Board
-
F221.2.1.1 General Seating
[ECTCR UFAS 4.1.2(18)(a) depending on assembly size] Table F221.2.1.1 Number of Wheelchair Spaces in Assembly Areas Number of Seats Minimum Number of Required Wheelchair...
-
7(2)(b)(v)
The top of the fixture rim is a maximum height of 2'10" above the finished floor. If kneespace is provided below the vanity, the bottom of the apron is at least 2'3" above the floor....
-
F203.4 Raised Areas
Areas raised primarily for purposes of security, life safety, or fire safety, including but not limited to, observation or lookout galleries, prison guard towers, fire towers, or life guard...
-
203.3 Raised Areas
Areas raised primarily for purposes of security, life safety, or fire safety, including but not limited to, observation or lookout galleries, prison guard towers, fire towers, or life guard...