Section 210.1 of the ADA Standards covers information in the current ADA Standards on scoping requirements for stairways.
Search Results "Clear Floor Area"
-
General: ADA Standard Section 210.1
-
§ 35.151(g)(2)
(2) Assembly areas that are required to horizontally disperse wheelchair spaces and companion seats by section 221.2.3.1 of the 2010 Standards and have seating encircling, in whole or in...
-
1009.4.3 Wall Depth and Length
The length of the transfer wall shall be 60 inches (1525 mm) minimum and shall be centered on the clear deck space....
-
11B-1009.4.3 Wall depth and length
The length of the transfer wall shall be 60 inches (1524 mm) minimum and shall be centered on the clear deck space....
-
11B-1009.4.3 Wall depth and length
The length of the transfer wall shall be 60 inches (1524 mm) minimum and shall be centered on the clear deck space....
-
Technical Memorandum TM 2013-21 Employee Work Areas
TM 2013-21 Employee Work Areas Effective Date: October 3, 2013 2012 TAS Reference: 203.9 and 206.2.8 ...
-
Basic Components for Accessible and Usable Public and Common Use Areas or Facilities
[See subsections ...]
-
Step-by-Step Guide
Step-by-Step Guide The following step-by-step guide has been provided to assist in evaluating a play area for meeting the minimum requirements of these guidelines. ...
-
Boat Slip Clearance: ADA Standard Section 1003.3.1
Boat slips shall provide clear pier space 60 inches (1525 mm) wide minimum and at least as long as the boat slips....
-
11B-1003.3.1 Boat slip clearance
Boat slips shall provide clear pier space 60 inches (1524 mm) wide minimum and at least as long as the boat slips....
-
11B-1003.3.1 Boat slip clearance
Boat slips shall provide clear pier space 60 inches (1524 mm) wide minimum and at least as long as the boat slips....
-
Slope: ADA Standard Section 1002.4.2
The floor or ground surface of wheelchair spaces shall have a slope not steeper than 1:48 when in the load and unload position....
-
11B-1002.4.2 Slope
The floor or ground surface of wheelchair spaces shall have a slope not steeper than 1:48 when in the load and unload position....
-
11B-1002.4.2 Slope
The floor or ground surface of wheelchair spaces shall have a slope not steeper than 1:48 when in the load and unload position....
-
1002.4.1 Floor or Ground Surface
The floor or ground surface of wheelchair spaces shall be stable and firm....
-
1002.4.1 Floor or Ground Surface
The floor or ground surface of wheelchair spaces shall be stable and firm....
-
Handrails: ADA Standard Section 1008.2.5.3
Where required on ramps serving play components, the handrails shall comply with 505 except as modified by 1008.2.5.3. EXCEPTIONS: 1. Handrails shall not be required on ramps...
-
11B-705.1.2.5 Blended transitions
Detectable warnings at blended transitions shall be 36 inches (914 mm) in width.
-
11B-1008.2.6.1 Accessibility
Ground surfaces shall comply with ASTM F 1951. Ground surfaces shall be inspected and maintained regularly and frequently to ensure continued compliance with ASTM F 1951.
-
11B-247.1.2.5 Blended transitions
11B-247.1.2.5 Blended transitions. Blended transitions shall have detectable warnings complying with Sections 11B-705.1.1 and 11B-705.1.2.5.
-
11B-247.1.2.5 Blended transitions
11B-247.1.2.5 Blended transitions. Blended transitions shall have detectable warnings complying with Sections 11B-705.1.1 and 11B-705.1.2.5.
-
11B-1008.2.6.1 Accessibility
Ground surfaces shall comply with ASTM F 1951. Ground surfaces shall be inspected and maintained regularly and frequently to ensure continued compliance with ASTM F 1951.
-
11B-705.1.2.5 Blended transitions
Detectable warnings at blended transitions shall be 36 inches (914 mm) in depth and extend the entirety of the transition separating the walk or sidewalk from the vehicular...
-
Section 810.2.2
Section 810.2.2 The Department recognizes that there will be some situations in which the full dimensions of a bus boarding and alighting area complying with the §810.2.2 may not be able...