Search Results "Clear Floor Area"
Commonly Searched Documents
- Figure 1009.2.2 Pool Lift Seat Location – Drawing from the U.S. Access Board
- Figure 1009.3.3 Handrails for Sloped Entry – Drawing from the U.S. Access Board
-
F221.2.1.1 General Seating
[ECTCR UFAS 4.1.2(18)(a) depending on assembly size] Table F221.2.1.1 Number of Wheelchair Spaces in Assembly Areas Number of Seats Minimum Number of Required Wheelchair...
-
7(2)(b)(v)
The top of the fixture rim is a maximum height of 2'10" above the finished floor. If kneespace is provided below the vanity, the bottom of the apron is at least 2'3" above the floor....
-
F203.4 Raised Areas
Areas raised primarily for purposes of security, life safety, or fire safety, including but not limited to, observation or lookout galleries, prison guard towers, fire towers, or life guard...
-
203.3 Raised Areas
Areas raised primarily for purposes of security, life safety, or fire safety, including but not limited to, observation or lookout galleries, prison guard towers, fire towers, or life guard...
-
4.4.1* GENERAL
Objects projecting from walls (for example, telephones) with their leading edges between 27 in and 80 in (685 mm and 2030 mm) above the finished floor shall protrude no more than 4 in (100...
-
T210.4 Location
Wheelchair spaces shall be located as near as practicable to doorways that provide a means of accessible boarding and alighting.
-
T215.2.3 Doorways
Doorways that provide a means of accessible boarding and alighting shall be identified on the exterior of the non-rail vehicle by the International Symbol of Accessibility complying...
-
Wheelchair Passage Width [4.2.1] and Passing Space [4.2.2]
A clear width of at least 48 inches (recommended but not required) allows for comfortable flow for people who use wheelchairs and people who are ambulatory....
-
Guest Room Doors and Doorways: ADA Standard Section 224.1.2
Section 224.1.2 covers scoping requirements in the current ADA Standards for transient lodging guest room doors and doorways.
-
Serving Counters
Serving Counters Where food or drinks are served at counters and the counter height is more than 34 inches above the floor, providing a lowered section of the serving counter at least...
-
A4.10.12 CAR CONTROLS
In many cases, it will be possible to locate the highest control on elevator panels with 48 in (1220 mm) from the floor....
-
§ 38.53(d)(3) Exception
Retrofitted vehicles shall be coordinated with the platform in new and key stations such that the horizontal gap shall be no greater than 4 inches and the height of the vehicle floor, under...
-
Residential Facilities: ADA Standard Section 203.8
Section 203.8 covers scoping requirements of general exceptions for residential facilities in the most current ADA Standards.
-
A4.10.12 Car Controls
In many cases, it will be possible to locate the highest control on elevator panels within 48 in (1220 mm) from the floor....
-
302.3 Openings
Openings in floor or ground surfaces shall not allow passage of a sphere more than 1/2 inch (13 mm) diameter except as allowed in 407.4.3, 409.4.3, 410.4, 810.5.3 and 810.10....
-
1013.2.1 Size
The clear ground space shall be 48 inches (1220 mm) wide minimum....
-
1013.2.1 Size
The clear ground space shall be 48 inches (1220 mm) wide minimum....
- GameTime ADA Wide Ramp Attachment 3D
-
11B-405.8 Handrails
[2010 ADAS] EXCEPTION: Within employee work areas, handrails shall not be required where ramps that are part of common use circulation paths are designed to permit the installation...