These guidelines provide optional design criteria based on children's dimensions. (As originally published, ADAAG requirements were based only on adult dimensions)....
Search Results "Maximum Dimension"
Commonly Searched Documents
-
ADAAG
-
Top Landings
The proposed rule specified that side flares of 1:12 maximum must be provided when space at the top of curb ramps is less than 48 inches long. This specification has been removed....
-
214 and 611 Washing Machines and Clothes Dryers
An exception will permit the maximum height for the tops of these machines to be 2 inches higher than the general requirement for maximum high reach over an obstruction....
-
Elevated Accessible Routes
inch (915 mm) clear width 32-inch (815 mm) narrowed width permitted for 24-inch (610 mm) length to accommodate features in the composite structure 12-inch (305 mm) rise maximum...
-
Play Tables
17 inches (430 mm) deep minimum Play tables designed primarily for children under 5 years old may provide a parallel approach instead of knee clearance if the rim is a maximum...
-
405.2 Slope
Table 405.2 Maximum Ramp Slope and Rise for Existing Sites, Buildings, and Facilities Slope1 Maximum Rise Steeper than 1:10 but not steeper than 1:8 3...
-
11B-604 Water closets and toilet compartments
INTERPRETATION Showers are fixtures including a 30 inch x 60 inch clear receptor with a minimum/maximum slope of ¼ inch per foot to a drain (refer to CPC Section 408.5 and CBC Section...
-
405.2 Slope
Table 405.2 Maximum Ramp Slope and Rise for Existing Sites, Buildings, and Facilities Slope¹ Maximum Rise Steeper than 1:10 but not...
-
711.3.1 Through penetrations
space between the penetrating item and the fire-resistance- rated wall shall be permitted to be protected as follows: In concrete or masonry walls where the penetrating item is a maximum...
-
405.2 Slope
Table 405.2 Maximum Ramp Slope and Rise for Existing Sites, Buildings, and Facilities Slope1 Maximum Rise Steeper than 1:10 but not...
-
608.6 Shower Spray Unit and Water
Shower spray units shall deliver water that is 120°F (49°C) maximum....
-
608.6 Shower Spray Unit and Water
Shower spray units shall deliver water that is 120°F (49°C) maximum....
-
11B-608.5.2 Standard roll-in type shower compartments
compartments, the controls, faucets, and the shower spray unit shall be located on the back wall of the compartment adjacent to the seat 16 inches (406 mm) minimum and 27 inches (686 mm) maximum...
-
Currently, the DCFC time limit is 30 minutes maximum. New larger battery capacity will take longer to get 80% charge – i.e. Chevy Bolt EV, Tesla Model 3, 2018 Nissan LEAF, etc. Can we reconsider the time limit?
RESPONSE: The 30 minute time limit applies to drive-up EVCS of any type. This design option allows brief charging and queuing for charging service, and does not consider that...
- Brady Worldwide Penalty $250 1st Offense Parking Sign 103713
-
210 Stairways
Such features include unique riser and tread dimensions and handrail configurations....
-
Wheelchair Accessible Gates
We increased the opening dimensions to meet Federal requirements in the United States....
-
5.4.2.2 Transfer and Positioning Support Length Recommendations for Imaging Equipment with Transfer Surfaces
Positioning Support Length Recommendations for Imaging Equipment with Transfer Surfaces On imaging equipment with transfer surfaces, the transfer surface is oriented along the long dimension...
-
5.3.2.2 Transfer Sides Recommendation for Imaging Equipment
5.3.2.2 Transfer Sides Recommendation for Imaging Equipment On imaging equipment, the transfer surface is oriented along the long dimension of the surface on which patients are in the...
-
Design Criteria for the Transfer Station
Transfer Station Design Criteria Design Element Dimensions Seat width ranges for platform 1 and 2 Adjustable between 18” and 30...
-
11B-609.3 Spacing
The distance between the grab bar and wall is an exact dimension. Many disabled people rely heavily upon grab bars to maintain balance and prevent serious falls. ...
-
1.1.17 Stairs
Measure stair riser height as the vertical dimension between tread nosings....
-
11B-609.3 Spacing
The distance between the grab bar and wall is an exact dimension. Many disabled people rely heavily upon grab bars to maintain balance and prevent serious falls....
-
11B-405.7.5 Doorways
Doors, in any position, shall not reduce the minimum dimension of the ramp landing to less than 42 inches (1067 mm). [2010 ADA Standards] 405.7.5 Doorways....