compartments, operable parts of controls and faucets shall be installed on the back wall of the compartment adjacent to the seat wall 19 inches (483 mm) minimum and 27 inches (686 mm) maximum...
Search Results "Maximum Dimension"
-
11B-608.5.2 Standard roll-in type shower compartments
-
11B-608.5.2 Standard roll-in type shower compartments
compartments, operable parts of controls and faucets shall be installed on the back wall of the compartment adjacent to the seat wall 19 inches (483 mm) minimum and 27 inches (686 mm) maximum...
-
11B-809.10.7.3 Reinforcement for grab bars
Where reinforcement is installed at the back, it shall be installed between 30 inches (762 mm) maximum and 38 inches (965 mm) minimum above the finish floor....
-
5.4.3 Transfer Support Height for M301 and M302
NPRM Preamble Discussion: The Access Board is considering whether 6 inches minimum and 19 inches maximum above the transfer surface would be an appropriate height for transfer supports on...
-
11B-1003.3.1 Boat slip clearance
Each 10 feet (3048 mm) maximum of linear pier edge serving boat slips shall contain at least one continuous clear opening 60 inches (1524 mm) wide minimum. Exceptions: 1....
-
11B-1003.3.1 Boat slip clearance
Each 10 feet (3048 mm) maximum of linear pier edge serving boat slips shall contain at least one continuous clear opening 60 inches (1524 mm) wide minimum....
-
1003.3.1 Boat Slip Clearance
Each 10 feet (3050 mm) maximum of linear pier edge serving boat slips shall contain at least one continuous clear opening 60 inches (1525 mm) wide minimum. EXCEPTIONS: 1....
-
Cross Slope (R302.6) (Section-by-Section Analysis)
The maximum cross slope permitted on accessible routes in the 2004 ADA and ABA Accessibility Guidelines is 2 percent....
-
3.3.14 Grip Strength
For those individuals able to complete the pinching tasks, the results showed that both the ability to perform a grip and the magnitude of maximum grip force are substantially affected by...
-
11B-604.3.2 Overlap
Notice CAN 2-11B, dated 9/9/14, which includes the following interpretation of Subsection 11B-604.3.2: Showers are fixtures including a 30 inch x 60 inch clear receptor with a minimum/maximum...
-
11B-604.3.2 Overlap
Notice CAN 2-11B, dated 9/9/14, which includes the following interpretation of Subsection 11B-604.3.2: Showers are fixtures including a 30 inch x 60 inch clear receptor with a minimum/maximum...
-
704.2.1.2 Forward Approach
Where a forward approach is provided, the distance from the front edge of a counter within the telephone enclosure to the face of the telephone unit shall be 20 inches (510 mm) maximum....
-
703.5.8 Character Spacing
Spacing between individual characters shall be 10 percent minimum and 35 percent maximum of character height....
-
§ 1194.25(j)(3)
(3) Where any operable control is more than 10 inches and not more than 24 inches behind the reference plane, the height shall be 46 inches maximum and 15 inches minimum above the floor....
-
703.5.8 Character Spacing
Spacing between individual characters shall be 10 percent minimum and 35 percent maximum of character height....
-
5.4.4 Transfer Support Distance From Transfer Surface for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
The transfer support should be located a maximum distance of 1½ inches from the transfer surface....
-
R403.4 Operation
The force required to activate operable parts shall be 22 N (5 lbs) maximum....
-
T304.3 Location
Operable parts provided at a wheelchair space shall be located adjacent to the wheelchair space 24 inches (610 mm) minimum and 36 inches (915 mm) maximum from the rear of the wheelchair...
-
T702.6 Character Spacing
Spacing between individual characters shall be 10 percent minimum and 35 percent maximum of character height....
-
407.6 Operation
The force required to activate operable parts shall be 5 pounds (22.2 N) maximum....
-
308.2.1 Unobstructed
Where a forward reach is unobstructed, the high forward reach shall be 48 inches (1220 mm) maximum and the low forward reach shall be 15 inches (380 mm) minimum above the finish floor or...
-
407.9 Operation
The force required to activate operable parts shall be 5 pounds (22.2 N) maximum....
-
8.4 Card Catalogs and Magazine Displays
Maximum reach height shall comply with 4.2, with a height of 48 in (1220 mm) preferred irrespective of approach allowed....
-
Incidental Rooms and Spaces
These can include work areas such as equipment control rooms, projection booths, radio and news booths, press boxes, and other occupiable spaces of incidental use where the maximum occupancy...