Elevator Car Requirements [§407.4.2 – §407.4.5] Other requirements for elevator cars include: compliant floor surfaces a maximum 1¼” horizontal clearance between car...
Search Results "Maximum Dimension"
Commonly Searched Documents
-
Elevator Car Requirements [§407.4.2 – §407.4.5]
-
11B-812.9 Surface marking
The centerline of the text shall be a maximum of 6 inches (152 mm) from the centerline of the vehicle space and its lower corner at, or lower side aligned with, the end of the parking space...
-
17) Visual alarms
Flash rate must be at a minimum of 1Hz and maximum of 3Hz (§4.28.3). UFAS: Contains much less detail. Allows faster flash rate of up to 5Hz (§4.28.3)....
-
11B-812.9 Surface marking
The centerline of the text shall be a maximum of 6 inches (152 mm) from the centerline of the vehicle space and its lower corner at, or lower side aligned with, the end of the vehicle space...
-
1118B.4
The maximum pile height shall be 1/2 inch (12.7 mm). See Figure 11B-7E(b)....
-
5.4.1.2 Transfer and Positioning Support Location Recommendations for Imaging Equipment with Transfer Surfaces
The Committee used a 24-inch dividing point for table width to accommodate the dimensions for the maximum reach range....
-
Clear Width: ADA Standard Section 404.2.3
Section 404.2.3 covers the current ADA Standards for clear width at manual doors, doorways and manual gates that are part of an accessible route.
-
Carpet: ADA Standard Section 302.2
Section 302.2 covers the current ADA Standards for carpet.
-
Turning Space: ADA Standard Section 809.2.2
EXCEPTION: Turning space shall not be required in exterior spaces 30 inches (760 mm) maximum in depth or width. Advisory 809.2.2 Turning Space....
-
11B-404.2.3 Clear width
Exceptions: In alterations, a projection of 5/8 inch (15.9 mm) maximum into the required clear width shall be permitted for the latch side stop....
-
11B-404.2.11 Vision lights
adjacent to doors or gates, containing one or more glazing panels that permit viewing through the panels shall have the bottom of at least one glazed panel located 43 inches (1092 mm) maximum...
-
11B-809.10.6.1 Size
A water closet shall be permitted to project 12 inches (305 mm) maximum into the opening provided that 36 inches (914 mm) minimum clear space is maintained between the water closet and the...
-
Extremely well done!
This video clearly demonstrates the length and dimension of what is expected but often misunderstood by contractors and architects....
-
Salsbury Industries See Through Metal Locker
Requires the Registered User plan or above. Login!
- Easter Seals El Mirador
- Don-Jo Mfg., Inc. Pull Plate 7010
- Hager Companies 5400 Series - Standard Duty Surface Door Closer
- BEA Inc. PBJMS Series Jamb Push Plate (Push to Open)
- Pressalit Care PLUS Support Arm Height Adjustable Swing Grab Bar
- Mockett TLKNB27 Original Kyros Leg 5" Base
- Pressalit Care PLUS Support Arm Height and Sideways Adjustable Swing Grab Bar
- Pressalit Care VALUE Support Arm Height Adjustable
- Bobrick Automatic Foam Dispenser B-8263
- Bobrick Automatic Liquid Soap Dispenser B-826