Interior hinged doors and gates: 5 pounds (22.2 N) maximum. 2. Sliding or folding doors: 5 pounds (22.2 N) maximum. 3....
Search Results "Maximum Dimension"
Commonly Searched Documents
-
11B-404.2.9 Door and gate opening force
-
11B-404.2.9 Door and gate opening force
The force for pushing or pulling open a door or gate other than fire doors shall be as follows: Interior hinged doors and gates: 5 pounds (22.2 N) maximum....
-
11B-1003.3.1 Boat slip clearance
Each 10 feet (3048 mm) maximum of linear pier edge serving boat slips shall contain at least one continuous clear opening 60 inches (1524 mm) wide minimum. Exceptions: 1. ...
-
1003.3.2 Boarding Pier Clearances
Every 10 feet (3050 mm) maximum of linear pier edge shall contain at least one continuous clear opening 60 inches (1525 mm) wide minimum. EXCEPTIONS: 1....
-
1003.3.1 Boat Slip Clearance
Each 10 feet (3050 mm) maximum of linear pier edge serving boat slips shall contain at least one continuous clear opening 60 inches (1525 mm) wide minimum. EXCEPTIONS: 1....
-
11B-1003.3.2 Boarding pier clearances
Every 10 feet (3048 mm) maximum of linear pier edge shall contain at least one continuous clear opening 60 inches (1524 mm) wide minimum. Exceptions: 1....
- KirbyBuilt Maxwell Recycled Plastic Picnic Table
-
505.4 Height
Top of gripping surfaces of handrails shall be 34 inches (865 mm) minimum and 38 inches (965 mm) maximum vertically above walking surfaces, stair nosings, and ramp surfaces....
-
307.2 Protrusion Limits
Objects with leading edges more than 27 inches (685 mm) and not more than 80 inches (2030 mm) above the finish floor or ground shall protrude 4 inches (100 mm) maximum horizontally into...
-
11B-1009.5.7 Grab bars
Where a grab bar is provided on each step, the tops of gripping surfaces shall be 4 inches (102 mm) minimum and 6 inches (152 mm) maximum above each step and transfer platform....
-
11B-307.2 Protrusion limits
Objects with leading edges more than 27 inches (686 mm) and not more than 80 inches (2032 mm) above the finish floor or ground shall protrude 4 inches (102 mm) maximum horizontally into...
-
307.2 Protrusion Limits
Objects with leading edges more than 27 inches (685 mm) and not more than 80 inches (2030 mm) above the finish floor or ground shall protrude 4 inches (100 mm) maximum horizontally into...
-
604.8.1.2 Doors
Where located in the front partition, the door opening shall be 4 inches (100 mm) maximum from the side wall or partition farthest from the water closet....
-
11B-703.4.1 Height above finish floor or ground
characters on signs shall be located 48 inches (1219 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest Braille cells and 60 inches (1524 mm) maximum...
-
Elevator Exemption
The 500 square foot maximum was based on a floor area allowance of 100 square feet per occupant, which is consistent with model building code requirements for business and industrial occupancies...
-
Table Surface Height
Persons with disabilities considered the 34 inch maximum height too high for surfaces used for any length of time....
-
1009.5.7 Grab Bars
Where a grab bar is provided on each step, the tops of gripping surfaces shall be 4 inches (100 mm) minimum and 6 inches (150 mm) maximum above each step and transfer platform....
-
Toilet Rooms-Special Exhibit Space
The force required to push or pull open the restrooms' vestibule doors is 10 lbf, which exceeds the maximum allowable door opening force of 5 lbf. See Standards § 4.13.11(2)(b). v....
-
Transfer Supports Location and Configuration M301.3 and M302.3
Transfer Supports Location and Configuration M301.3 and M302.3 Location of the transfer supports shall be a minimum of 6 inches to a maximum of 19 inches from the top of the transfer...
-
R302.6.1 Pedestrian Street Crossings Without Yield or Stop Control
Where pedestrian access routes are contained within pedestrian street crossings without yield or stop control, the cross slope of the pedestrian access route shall be 5 percent maximum....
-
505.4 Height
Top of gripping surfaces of handrails shall be 34 inches (865 mm) minimum and 38 inches (965 mm) maximum vertically above walking surfaces, stair nosings, and ramp surfaces....
-
604.8.1.2 Doors
Where located in the front partition, the door opening shall be 4 inches (100 mm) maximum from the side wall or partition farthest from the water closet....
-
11B-505.4 Height
Top of gripping surfaces of handrails shall be 34 inches (864 mm) minimum and 38 inches (965 mm) maximum vertically above walking surfaces, stair nosings, and ramp surfaces....
-
11B-406.3.2 Turning space
The slope of the turning space in all directions shall be 1:48 maximum. FIGURE 11B-406.3.2 ‡‡ PARALLEL CURB RAMPS...