Men’s toilet and bathing facilities shall be identified by an equilateral triangle, ¼ inch (6.4 mm) thick with edges 12 inches (305 mm) long and a vertex pointing upward. The...
Search Results "Signage"
Commonly Searched Documents
-
11B-703.7.2.6.1 Men’s toilet and bathing facilities
-
11B-703.7.2.6.2 Women’s toilet and bathing facilities
Women’s toilet and bathing facilities shall be identified by a circle, ¼ inch (6.4 mm) thick and 12 inches (305 mm) in diameter. The circle symbol shall contrast with the door,...
-
11B-703.7.2.6.3 Unisex toilet and bathing facilities
Unisex toilet and bathing facilities shall be identified by a circle, ¼ inch (6.4 mm) thick and 12 inches (305 mm) in diameter with a ¼ inch (6.4 mm) thick triangle with a vertex...
-
11B-703.7.2.6 Toilet and bathing facilities geometric symbols
Doorways leading to toilet rooms and bathing rooms shall be identified by a geometric symbol complying with Section 11B-703.7.2.6. The symbol shall be mounted at 58 inches (1473 mm)...
-
Which Paths Lead to Usable Circulation Paths?
Any circulation paths that are not usable should include signs directing people to other, usable paths. People with limited mobility should be provided with written directions, a...
-
11B-703.7.2.6.4 Edges and corners
Edges of signs shall be rounded, chamfered or eased. Corners of signs shall have a minimum radius of 1/8 inch (3.2 mm).
-
11B-703.7.2.6 Toilet and bathing facilities geometric symbols
11B-703.7.2.6 Toilet and bathing facilities geometric symbols. Geometric symbols at entrances to toilet and bathing rooms shall be mounted at 58 inches (1473 mm) minimum and 60...
-
11B-703.7.2.6.4 Edges and vertices on geometric symbols
11B-703.7.2.6.4 Edges and vertices on geometric symbols. Edges shall be eased or rounded at 1/16 inch (1.59 mm) minimum, or chamfered at 1/8 inch (3.2 mm) maximum. Vertices shall be...
-
11B-703.7.2.6 Toilet and bathing facilities geometric symbols
Geometric symbols at entrances to toilet and bathing rooms shall be mounted at 58 inches (1473 mm) minimum and 60 inches (1524 mm) maximum above the finish floor or ground surface...
-
11B-703.7.2.6.4 Edges and vertices on geometric symbols
Edges shall be eased or rounded at 1/16 inch (1.59 mm) minimum, or chamfered at 1/8 inch (3.2 mm) maximum. Vertices shall be radiused between 1/8 inch (3.2 mm) minimum and ¼ inch...
- Access Board: Tactile Sign Height
-
11B-502.6.2 Minimum fine
Additional language or an additional sign below the International Symbol of Accessibility shall state “Minimum Fine $250.”
-
Signs
Signs • Signs that identify permanent rooms and spaces, such as those identifying rest rooms, exits or room numbers, must have Braille and raised letters or numbers so that they...
-
11B-502.6.4 Marking
Each accessible car and van space shall have surface identification complying with either Section 11B-502.6.4.1 or 11B-502.6.4.2.
-
11B-502.6.2 Minimum fine
Additional language or an additional sign below the International Symbol of Accessibility shall state “Minimum Fine $250.”
-
11B-502.6.4 Marking
Each accessible car and van space shall have surface identification complying with either Section 11B-502.6.4.1 or 11B-502.6.4.2.
-
11B-502.6.2 Minimum fine
Additional language or an additional sign below the International Symbol of Accessibility shall state “Minimum Fine $250.”
-
11B-502.6.4 Marking
Each accessible car and van space shall have surface identification complying with either Section 11B-502.6.4.1 or 11B-502.6.4.2.
-
Van Accessible Signage
Comment. The proposed rule removed a requirement that the access designation for van parking include the term "van accessible" to clarify that both car and van drivers can use such...
-
Van Accessible Signage
Comment. The proposed rule removed a requirement that the access designation for van parking include the term "van accessible" to clarify that both car and van drivers can use such...
-
1009.9 Signage
Signage indicating special accessibility provisions shall be provided as shown: Each door providing access to an area of refuge from an adjacent floor area shall be identified by a...
-
11B-216.8.1 Geometric symbols
Geometric symbols complying with Section 11B-703.7.2.6 shall be provided at entrances to toilet and bathing rooms. Exceptions: Geometric symbols shall not be required at...
-
A. Signs
A. If signs are provided for the following spaces, are the signs mounted on the wall (not the door) to the latch side of the door and centered 60" above the floor so that they can be...
-
11B-703.1.1.2 Inspection
Signs and identification devices shall be field inspected after installation and approved by the enforcing agency prior to the issuance of a final certificate of occupancy per...