2025 California Standards for Accessible Design Guide (effective January 1, 2026)
11B-806.2 Guest rooms with mobility features.
Guest rooms required to provide mobility features shall comply with Section 11B-806.2.
11B-806.2.1 Living and dining areas.
Living and dining areas shall be accessible.
11B-806.2.2 Exterior spaces.
Exterior spaces, including patios, terraces and balconies that serve the guest room shall be accessible.
11B-806.2.3 Sleeping areas.
At least one sleeping area shall provide a 36 inch (914 mm) by 48 inch (1219 mm) minimum clear space on both sides of a bed. The clear space shall be positioned for parallel approach to the side of the bed.
[2010 ADA Standards] 806.2.3 Sleeping Areas. At least one sleeping area shall provide a clear floor space complying with 305 on both sides of a bed. The clear floor space shall be positioned for parallel approach to the side of the bed.
Exception: Where a single clear floor space complying with Section 11B-305 positioned for parallel approach is provided between two beds, a clear floor or ground space shall not be required on both sides of a bed.
11B-806.2.3.1 Personal lift device floor space.
In transient lodging facilities, clearance for the use of a personal lift device shall be provided under the bed(s) and adjacent to the clear floor space required by Section 11B-806.2.3. The clearance shall be parallel to the long side of the bed and extend under the bed to points horizontally 30 inches (762 mm), vertically 7 inches (178 mm) and not more than 12 inches (305 mm) from the head and foot end of the bed.
ETA Editor's Note
The clearance prescribed for a personal lift device at CBC 11B-806.2.3.1 is not required by 2010 ADA Standards.
From DSA's "Summary of New and Amended 2025 California Building Code (CBC) Regulations for Accessibility in the Triennial Code Cycle: "Language was amended to clarify that the California-specific requirements for the clearance for a personal lift device is applicable to transient lodging facilities only, and not to housing at a place of education."
11B-806.2.4 Toilet and bathing facilities.
At least one bathroom that is provided as part of a guest room shall comply with Section 11B-603. No fewer than one water closet, one lavatory, and one bathtub or shower shall comply with applicable requirements of Sections 11B-603 through 11B-610. In addition, required roll-in shower compartments shall comply with Section 11B-608.2.2 or 11B- 608.2.3. Toilet and bathing fixtures required to comply with Sections 11B-603 through 11B-610 shall be permitted to be located in more than one toilet or bathing area, provided that travel between fixtures does not require travel between other parts of the guest room.
11B-806.2.4.1 Vanity counter top space.
If vanity counter top space is provided in non-accessible guest bathrooms, toilet or bathing rooms, comparable vanity counter top space, in terms of size and proximity to the lavatory, shall also be provided in accessible guest bathrooms, toilet or bathing rooms.
ETA Editor's Note:
From DSA's "Summary of New and Amended 2025 California Building Code (CBC) Regulations for Accessibility in the Triennial Code Cycle: "Addition of the word “bathrooms” to existing “toilet and bathing rooms” language, to denote that the requirement for vanity counter top space is applicable to both transient lodging facilities and housing at a place of education."
11B-806.2.5 Kitchens, kitchenettes and wet bars. Kitchens, kitchenettes and wet bars shall comply with Section 11B-804.
[2010 ADA Standards] 806.2.5 Kitchens and Kitchenettes. Kitchens and kitchenettes shall comply with 804.
11B-806.2.6 Turning space.
Turning space complying with Section 11B-304 shall be provided within the guest room.