Hello. Please sign in!

Note: This document or portion of document references a state or local requirement that is NOT required by the 2010 ADA Standards.

11B-806.2.3.1 Personal lift device floor space.

In transient lodging facilities, clearance for the use of a personal lift device shall be provided under the bed(s) and adjacent to the clear floor space required by Section 11B-806.2.3. The clearance shall be parallel to the long side of the bed and extend under the bed to points horizontally 30 inches (762 mm), vertically 7 inches (178 mm) and not more than 12 inches (305 mm) from the head and foot end of the bed.

ETA Editor's Note

The clearance prescribed for a personal lift device at CBC 11B-806.2.3.1 is not required by 2010 ADA Standards.

From DSA's "Summary of New and Amended 2025 California Building Code (CBC) Regulations for Accessibility in the Triennial Code Cycle: "Language was amended to clarify that the California-specific requirements for the clearance for a personal lift device is applicable to transient lodging facilities only, and not to housing at a place of education."